2.1 Opening ......102 the version). 2.2 Power supply ....102 • The operating differences with former ranges are described in the compatibility booklet available in the Daitem installers section at 3. Programming......103 www.daitem.co.uk. 4. Configuration......104 The multicontact detector is used 5.
Page 3
Choosing the external contact type In the default configuration the type of contact chosen automatically pre-determines the level of alarm generated. Nevertheless, it is possible to modify the alarm level for the built-in or external contact(s) (see § on Configuration). Application example: a side door and garage The built-in magnetic contact The wide gap external magnetic...
2. Preparation 2.1 Opening 2.2 Power supply The lithium battery pack is clipped into position (see 1. Loosen the screws using a cross-head diagram below). An arrow indicates which way to screwdriver. connect it. 2. Unclip the base plate cover. Connection terminals for external...
3. Programming 2. Programme the device as follows During recognition program-ming, the product to be programmed for use “detector X” “group ?” “time delay?” “beep, detector X, with the control panel does not need group Y to be placed next to it. In fact, we immediate recommend you place the product at a (or delayed...
4. Configuration Configuring the multicontact detector enables the characteristics of the 2 IMPORTANT contacts (built-in and external) to be defined. • The cover must be open when To configure the contacts: configuring the detector. • An unused built-in or external •...
Page 7
• Follow the configuration sequence described below: LED indicator lamp lit LED indicator about lamp not lit about 10 sec. about 10 sec. about 2 sec. 5 sec. Sequence To start the Press as many times Press & hold Press as many times To end LED Indicator sequence press &...
Page 8
Checking configuration: the contact is checked by selecting the Parameter n° and then checking the number of times the indicator lamp flashes. Start Press 3 times to select Press once 2 flashes confirm that the the external contact to accept roller shutter blind contact has selection been correctly configured...
Page 9
The type of contact chosen automatically pre- Type Parameter Contact Parameter determines the level of alarm generated. of contact n° characteristics vaue Nevertheless, it is possible to modify this alarm level. intrusion Built-in To configure the alarm level: prealert • choose the parameter number to match the contact to be configured, deterrence •...
6. Installing Example 4 Connection of a roller IMPORTANT: make sure there is a distance of at least shutter blind sensor 1 2 3 2 m between each product, except between 2 detectors. (mainly used in the continent and not the UK) 6.1 Choosing the best place The multicontact detector must be placed: •...
Installing the magnet holder Cable grommets When the entrance is closed the magnet holder must be positioned opposite the built-in contact less than 5 mm away from it. 1. Align the vertical slot on the 2. Adjust the height of the magnet holder with the arrow magnet holder according to located on the base of the...
Page 13
Overview of opening and closing distances between the multicontact 3. Fix the magnet holder base, detector and the magnet used by the built-in contact to analyse any place the magnet inside the change in entrance status. cover and clip it to the base. Built-in contact opening and closing distances Movement Contact...
6.4 Connecting external contacts Surface Cover Surface or flush-mounted encapsulated cabled contact Magnet contacts Base • NC loop with anti-tamper loop: yellow screwed - yellow and red wires: to door Contact anti-tamper loop, green Spacers Base - green and blue wires: screwed blue detection loop.
Page 15
Piezo-electric glassbreak sensor Contact • NC loop type. Position magnet of magnet • Suitable for all types of glass with a thickness of up to 6 mm. • Detection: up to 2.5 m from the point of impact. • Operating temperature: - 18°C to + 38°C. Possible Incorrect magnet...
Large and small model 7. Testing waterproof pressure mats • NO loop type. The multicontact detector has a “test” mode for testing: • Minimum weight for contact • the battery: the LED indicator lamp lights up when the test button is closing: pressed to indicate the battery is working correctly, - small model: 35 kg...
Page 17
To test the detector: 1. connect the lithium battery pack, 2. clip and screw the detector casing to its base, 3. press the test button and the detector changes to test mode for about 90 sec. After this period the detector automatically returns to normal operating mode, In accordance with the new functional requirements of EN50131-2-6, the LED is factory defaulted to be Inactive in Test Mode.
DAITEM shall not be held • To test glassbreak detectors, carefully tap sharply on the responsible for any problems. window using the handle of a large...
• The lithium battery pack must be replaced by the same type of pack with the same technical characteristics (BatLi31 3 V - 1 Ah). • We advise you to use the DAITEM BatLi31 pack available in the catalogue in order to guarantee individual safety and equipment reliability.
Built-in magnetic contact Terminal block for external contact Environment building interior Power supply DAITEM 3 V lithium battery BatLI31 Battery life 5 years in normal conditions of use Average humidity rate 5% to 75% without condensation at 25°C Radio links...
Page 21
Used on Product type: Multicontact detector products or product packaging, this symbol indicates that Trade mark: Daitem We declare under our sole responsibility that the product to which this the product must not be thrown out with household waste.
Need help?
Do you have a question about the SH271AX and is the answer not in the manual?
Questions and answers