Eaton is a registered trademark of Eaton Corporation or its subsidiaries and affiliates. ECopyright 2015 Eaton Corporation, Raleigh, NC, USA. All rights reserved. No part of this document may be reproduced in any way without the express written approval of Eaton Corporation.
Engineer, or the warranty terms specified on page W-1 become void. This service is offered as part of the sales contract for the FI-UPM. Contact an Eaton service representative in advance (usually a two-week notice is required) to request service.
For More Information Refer to the following manuals for additional information: Eaton Power Xpert 9395P UPS (650 900 kVA) Installation and Operation Manual Eaton Power Xpert 9395P UPS (1000-1200 kVA) Installation and Operation Manual These manuals describe:...
A question this manual does not answer Please call the Eaton Help Desk at: 1-800-843-9433 1-919-870-3028 United States: 1-800-461-9166 ext 260 Canada: Call your local service representative All other countries: Power Xpert 9395P Field Installed UPM Mechanical Installation Manual P-164000503 Rev 1...
Keep the FI-UPM front panel installed to ensure proper cooling airflow and to protect personnel from dangerous voltages inside the unit. Do not install or operate the UPS system or FI-UPM close to gas or electric heat sources. Power Xpert 9395P Field Installed UPM Mechanical Installation Manual P-164000503 Rev 1...
Page 12
Maintenir les lieux rangés, propres et exempts d’une humidité excessive. Respecter les étiquettes DANGER, MISE EN GARDE et AVERTISSEMENT se trouvant à l’intérieur et à l’extérieur de l’équipement. Power Xpert 9395P Field Installed UPM Mechanical Installation Manual P-164000503 Rev 1...
Engineer, or the warranty terms specified on page W-1 become void. This service is offered as part of the sales contract for the FI-UPM. Contact an Eaton service representative in advance (usually a two-week notice is required) to request service.
Page 14
Cooling Air Exhaust 225 kVA 480/480 7.9 (27.1) Approximately 250 kVA 480/480 9.3 (31.9) 950 liter/sec 275 kVA 480/480 10.6 (36.1) (2000 CFM) 480/480 10.6 (36.1) 300 kVA Power Xpert 9395P Field Installed UPM Mechanical Installation Manual P-164000503 Rev 1...
FIELD INSTALLED UPM INSTALLATION PLAN AND UNPACKING 1880 [74.0] 735.9 [29.0] Dimensions are in millimeters [inches]. Figure 3‐1. FI-UPM Cabinet Dimensions (Front View) Power Xpert 9395P Field Installed UPM Mechanical Installation Manual P-164000503 Rev 1...
Carefully inspect the outer packaging for evidence of damage during transit. C A U T I O N Do not install a damaged cabinet. Report any damage to the carrier and contact an Eaton service representative immediately. A T T E N T I O N ! Ne pas installer une armoire endommagée.
Page 19
Inspect the contents for any evidence of physical damage, and compare each item with the Bill of Lading. If damage has occurred or shortages are evident, contact an Eaton service representative immediately to determine the extent of the damage and its impact on further installation.
FIELD INSTALLED UPM INSTALLATION PLAN AND UNPACKING Figure 3‐7. Power Xpert 9395P FI-UPM Cabinet as Shipped on Pallet Power Xpert 9395P Field Installed UPM Mechanical Installation Manual P-164000503 Rev 1...
A T T E N T I O N ! Ne pas incliner les armoires à plus de 10 degrés de la verticale. Ne soulever les armoires qu’à l’aide d’un chariot élévateur pour éviter de les endommager. Power Xpert 9395P Field Installed UPM Mechanical Installation Manual P-164000503 Rev 1...
Using a forklift, raise the FI-UPM cabinet section until the cabinet bottom clears the pallet by approximately 3 mm (1/8”). Pull the pallet from under the FI-UPM cabinet. Power Xpert 9395P Field Installed UPM Mechanical Installation Manual P-164000503 Rev 1...
UPS cabinet. Verify that the FI-UPM cabinet right side is against the UPS cabinet left side and the front panels are flush with each other. Carefully lower the FI-UPM cabinet until the cabinet base contacts the floor. Power Xpert 9395P Field Installed UPM Mechanical Installation Manual P-164000503 Rev 1...
UPS Front Wire Entry Plate Remove plate to route wires between cabinets. LEFT SIDE VIEW Figure 4‐3. UPS Cabinet Wire Entry Plate and Knockout Locations Power Xpert 9395P Field Installed UPM Mechanical Installation Manual P-164000503 Rev 1...
Service Engineer, or the warranty terms specified on page W-1 become void. This service is offered as part of the sales contract for the FI-UPM. Contact an Eaton service representative in advance (usually a two-week notice is required) to reserve a preferred startup date.
UPS equipment. - The debris shield covering the FI-UPM cabinet ventilation grill is removed. - Startup and operational checks are performed by an authorized Eaton Customer Service Engineer. Power Xpert 9395P Field Installed UPM Mechanical Installation Manual P-164000503 Rev 1...
Page 28
FIELD INSTALLED UPM INSTALLATION This page intentionally left blank. Power Xpert 9395P Field Installed UPM Mechanical Installation Manual P-164000503 Rev 1...
Page 29
Eaton-built battery cabinets, (individually and collectively, the ”Warranted Items”) are free from defects in material and workmanship. If, in the opinion of Eaton, a Warranted Item is defective and the defect is within the terms of this Warranty, Eaton’s sole obligation will be to repair or replace such defective item (including by providing service, parts and labor, as applicable), at the option of Eaton.
Page 30
WARRANTY This page intentionally left blank. Power Xpert 9395P Field Installed UPM Mechanical Installation Manual P-164000503 Rev 1...