Operation
2.
Warning!
Always ensure that the machine's handle is in the upright position when the
machine is tipped to enable access beneath the grinding head. Otherwise, there
is a risk that the machine could fall back and cause personal injury.
Adjust and lock the chassis in the desired position, using the locking mechanism,
see pos. 4 Figure 3-2, page 10.
Adjust the handle to the desired angle to achieve the best ergonomics, see pos. 1
Figure 3-2,
4.3

Access to grinding tools

Warning!
During grinding, the tools become very hot. Tip the machine back and allow it
to stand for a short while. Use protective gloves when removing the tools.
Warning!
 Disconnect the electrical supply when cleaning, carrying out maintenance,
changing tools or repairing the machine.
1.
Set the handle to the upright position - see Figure 4-1,
2.
Tip the machine backwards carefully so that it rests on the floor.
4.4

Fitting and replacing grinding tools

As the machine is equipped with the patented EZchange tool system, fitting and
replacing grinding tools is quick and easy. The tool system consists of wings on which
diamond grinding tools are fitted without the need for screws.
Warning!
 Disconnect the electrical supply when cleaning, carrying out maintenance,
changing tools or repairing the machine.
Warning!
During grinding, the tools become very hot. Tip the machine back and allow it
to stand for a short while. Use protective gloves when removing the tools.
Note!
Check that the motor's direction of rotation agrees with the direction arrow on
the motor when using tools that are sensitive to the direction.
14
Working position - the working height can be adjusted to one of several
positions with the machine's adjustable handle
page 10
using the supplied Allen key.
HTC GL 270 HD
page 13