Download Print this page

THERMOROSSI ecotherm 3001 Installation, Use And Maintenance Manual

Hide thumbs Also See for ecotherm 3001:

Advertisement

THE FIRST TALKING HEATER
INSTALLATION, USE AND MAINTENANCE GUIDE
ECOTHERM 3001
36011 Arsiero (VI) ITALY - Via Grumolo ,4 -
www.thermorossi.com

Advertisement

loading

Summary of Contents for THERMOROSSI ecotherm 3001

  • Page 1 THE FIRST TALKING HEATER INSTALLATION, USE AND MAINTENANCE GUIDE ECOTHERM 3001 36011 Arsiero (VI) ITALY - Via Grumolo ,4 - www.thermorossi.com...
  • Page 2 Charging the handheld radio control battery SMOKE DISCHARGE TUBE Ventilation of the room Smoke outlet VOICE ALARMS ELECTRICAL WIRING INFORMATION FOR THE SKILLED TECHNICIAN 12.1 Main components and their operation 12.2 Useful advice for installation and operation 12.3 Troubleshooting ECOTHERM 3001 SPARE PARTS pg. 2...
  • Page 3: Ce Declaration Of Conformity

    92/31/EEC 93/97/EEC Thermorossi S.p.A., Via Grumolo 4 - ARSIERO (VI), declares that the heaters of the ECOTHERM series have been designed and manufactured in compliance with the safety requirements of the standards for EC marking. This declaration refers to the entire range of the specified series.
  • Page 4 °If the appliance is sold or transferred to another user ensure that the guide is handed over with it. Thermorossi S.p.A. maintains the author’s rights on these service instructions. The information in this booklet may not be reproduced or given to third parties or used for competitive purposes without the appropriate authorization.
  • Page 5: Technical Characteristics

    2 2 2 2 2 TECHNICAL CHARACTERISTICS TECHNICAL CHARACTERISTICS TECHNICAL CHARACTERISTICS TECHNICAL CHARACTERISTICS TECHNICAL CHARACTERISTICS ECOTHERM 3001 METALCOLOR ECOTHERM 3001 EASY Power min /max 2.5-9 Kw Power min /max 2.5-9 Kw Smoke Temperature 220 °C Smoke Temperature 220 °C Average smoke flow rate 9.3 g/s...
  • Page 6: General Description

    3 3 3 3 3 GENERAL GENERAL GENERAL GENERAL GENERAL DESCRIPTION DESCRIPTION DESCRIPTION DESCRIPTION DESCRIPTION 3 . 1 3 . 1 OPERA OPERA TING TING TECHNOL TECHNOL 3 . 1 3 . 1 3 . 1 OPERA OPERA OPERATING TING TING TECHNOL TECHNOL...
  • Page 7 5 5 5 5 5 HANDHELD RADIO CONTROL HANDHELD RADIO CONTROL HANDHELD RADIO CONTROL HANDHELD RADIO CONTROL HANDHELD RADIO CONTROL 5 . 1 5 . 1 5 . 1 5 . 1 5 . 1 DESCRIPTION OF DESCRIPTION OF DESCRIPTION OF THE DESCRIPTION OF DESCRIPTION OF THE ALADINO HANDHELD RADIO CONTR...
  • Page 8 5 . 1 . 3 5 . 1 . 3 5 . 1 . 3 ALADINO ALADINO ALADINO Indicators Indicators Indicators 5 . 1 . 3 5 . 1 . 3 ALADINO ALADINO Indicators Indicators (5) “Room temperature detected by the radio control’s temperature sensor” indicator . (6) “Ventilation level “...
  • Page 9 5.1.4 5.1.4 BA A A A A CK ANEL OF ANEL OF THE HEA THE HEA 5.1.4 5.1.4 5.1.4 PANEL OF ANEL OF ANEL OF THE HEA THE HEA THE HEATER The back panel integrates the radio control. A description of the functions of the buttons and LEDs on the back panel of the heater: (20) Heater on/off and flame adjustment button .
  • Page 10 ON/OFF PROGRAMMING. ON/OFF PROGRAMMING. ON/OFF PROGRAMMING. ON/OFF PROGRAMMING. ON/OFF PROGRAMMING. The heater must be energised and the switch at the back in position “1”. The weekly programming can be executed with the help of the handheld radio control. It is possible to set up to 3 on-off cycles for each day from Monday to Sunday.
  • Page 11 5.7 D 5.7 D 5.7 D 5.7 D 5.7 DA A A A A T T T T T A A A A A A N A NA L A LY Y Y Y Y SIS DATA ANALYSIS represents the function concerning update of data between the heater and the Aladino radio control. The radio wave transmission is frequently used by numerous applications: the DATA ANALYSIS function is used to update the temperature, ventilation, power, temperature analysis, system status.
  • Page 12 The guarantee does not apply if the defect is caused by non-conforming use and/or if the instructions and guidelines described above are not observed to the letter. Non-conformities must be reported within two months of having identified them.Devices or parts returned for replacement become the property of Thermorossi. 6 6 6 6 6...
  • Page 13 CAUTION : The start up phase (word ON appearing on the display) takes 20 minutes during which the heater ignores any commands transmitted to it. After this time has elapsed the word RUNNING appears on the display. The fan starts as soon as the heater body exceeds 42°C.
  • Page 14: Cleaning And Maintenance

    “Perry”. Caution: In the event of connections to the chronothermostat Thermorossi shall not be held responsible for the heater not starting up, smoke leaks, breakage of the lighting component. In the event of a programmed cycle on always ensure that the brazier is clean and seated correctly in its lodging.
  • Page 15 It is completely normal during the battery recharge process for symbols and/or lines to appear haphazardly on the display. Caution: Use only the battery charger provided by Thermorossi. The use of any other type of battery charger will invalidate the product warranty.
  • Page 16 9 . 2 9 . 2 9 . 2 9 . 2 9 . 2 SMOKE OUTLET SMOKE OUTLET SMOKE OUTLET SMOKE OUTLET SMOKE OUTLET •The smoke outlet shown in the following figures is the best solution to ensure the discharge of smoke even when the fan is not operational, such as for example if there is an electrical power failure.A minimum drop of 1.5 metres is required between the T terminal on the outside of the building and the outlet at the back of the appliance, to ensure that residual combustion smoke is discharged in the case described above (Otherwise the residues would stagnate inside the firebox...
  • Page 17 VOCAL ALARMS VOCAL ALARMS VOCAL ALARMS VOCAL ALARMS VOCAL ALARMS The heater is programmed to communicate 4 fundamental alarms. The vocal alarm is transmitted 4 times in rapid succession . It is transmitted in the following languages: Italian, English, German, French. These situations are repeated two more times a few minutes apart. If , however, the alarm is zeroed it will not be communicated.
  • Page 18 INFORMA INFORMA TION FOR TION FOR THE SKILLED THE SKILLED TECHNICIAN TECHNICIAN INFORMA INFORMATION FOR INFORMA TION FOR TION FOR THE SKILLED THE SKILLED THE SKILLED TECHNICIAN TECHNICIAN TECHNICIAN 12.1 MAIN COMPONENTS AND THEIR OPERATION SMOKE PRESSURE SWITCH This is a safety switch that stops the screw feeder motor whenever necessary. The main cause for the pressure switch tripping is a blocked flue outlet or smoke exhaust pipe.
  • Page 19 EMPTY THE BURNER AND FILL UP THE THERE ARE UNBURNT TANK PELLETS IN THE BRAZIER THE HEATER EXECUTES THERE IS ANOTHER THERMOROSSI HEATER CHANGE THE CODE SELECTOR (SEE PARA. COMMANDS THAT HAVE INSTALLED IN THE VICINITY OF THIS 5.10). NOT BEEN SET HEATER pg.
  • Page 20 THERM 3001 SPARE P ARE P ARE PAR ARTS FOR ECO TS FOR ECO TS FOR ECOTHERM 3001 THERM 3001 THERM 3001 6001 1 767 - N E R A 60011767 - BLACK 6001 1 768 - B E IG E...
  • Page 21 700 0 45 3 7 P O R T A C O M P L E T A 70004537 COMPLETE DOOR 70 01 2277 70012277 700 1 1 24 0 P O R T A G H IS A 70011240 CAST IRON DOOR 70 01 2276 70012276...
  • Page 22 7001 0402 7001 03 25 7001 023 4 6001 1 776 R A D IO C O M A N D O A L A D IN O 6001 1 246 60011776 ALADINO RADIO CONTROL 6001 1 787 B A T T E R IA R IC A R IC A B IL E R A D IO C O M A N D O 60011787 RADIO CONTROL RECHARGEABLE BATTERY 6001 1 788 C A R IC A B A T T E R IA R A D IO C O M A N D O 60011788 RADIO CONTROL BATTERY CHARGER...