Installing and Preparing the C7
4. Select the STOP function by pressing
5. Select the MRES (Memory Reset) function by pressing
6. Immediately after the STOP LED lights up again:
7. Following the memory reset, you must set the C7 CPU explicitly to STOP
Note
A memory reset does not affect the content of the C7 CPU flash memory.
How to delete the content of the flash memory is described in Volume 2,
Section 3.8.
2-22
The following menu is displayed.
MODE:STOP
RUNP RUN STOP MRES
SF
DC5V
FRCE
Figure 2-18
"C7 CPU Modes" Menu with Function Keys
The STOP LED lights up.
until the STOP LED goes off twice.
Select STOP and immediately afterwards MRES (within 1 second). If
there is more than 1 second between pressing the two keys, the memory
reset is not performed.
Result:
– When the STOP LED flashes quickly for approximately 3 seconds and
is then lit continuously again, the memory on the C7 CPU has been
reset.
– If the STOP LED of the C7 lights up without first flashing, then repeat
Steps 4 and 5.
or RUN/RUNP otherwise the C7 CPU is still set to MRES.
= Anwahl der
DIR–Funktion
RUN
LED displays
STOP
.
and wait