Using the STARTER Control Panel (Motor Rotates)
Fig. 4-6
2. Click Assume control priority to connect the control panel to the drive inter-
face.
Note the message that is then displayed in the Control priority dialog screen.
This message is very important (see also Fig. 4-7).
Danger
!
Use control priority with care!
The function should be used for commissioning, diagnostics, and maintenance
purposes only.
Make sure that the drive is in the "OFF" status and that no ON/OFF1 command
has been issued either by the control word for sequence control or another signal
source (e.g. BICO interconnection).
Once control priority has been transferred to the PC, the BICO interconnections on
bit 1 to bit 6 of the control word are no longer active.
4-60
Click Assume control priority.
Assuming control priority
SINAMICS S120 Getting Started with the STARTER Commissioning Tool – 03/2006 Edition