POWER SUPPLY - AGA TC3/TC5 (ROOM VENT OPTION)
WARNING: THIS APPLIANCE MUST BE EARTHED.
THIS APPLIANCE IS DESIGNED FOR THE VOLTAGE STATED ON THE RATING PLATE,
WHICH IS SITUATED BEHIND THE PLINTH COVER.
IF THE SUPPLY CORD IS DAMAGED, IT MUST BE REPLACED BY THE MANUFACTURER,
ITS SERVICE AGENT OR SIMILARLY QUALIFIED PERSON TO AVOID A HAZARD.
A 1PH 32 amp 230V or 3PH 400V minimum 16A per phase ~ 50 Hz fused electrical supply is
required adjacent to the appliance. For single phase connection a minimum cable size of 6mm
2
is to be used between cooker cable connection point and the home's main distribution board.
External wiring to the unit must be installed using the mains cable provided, in accordance with
the current wiring regulations and any local regulations which apply. If cable is shortened, new
ferrules must be fitted to the stripped conductors.
The method of connection to the mains electricity supply must facilitate complete electrical
isolation of the appliance, by a multi-pole switch, having a contact separation of at least 3mm on
all poles.
The isolator should not be positioned immediately above the cooker, but must be fitted within 2
metres of the appliance.
The isolator maybe separate from the connection point.
The mains connection point must be accessible within the areas shown in Fig 3A, Page 8 for
cable routing options.
For 2 or 3 phase installations an optional adaptor kit must be obtained (Part No. AE4M280354).
POWER SUPPLY - HOTCUPBOARD (AGA TC5)
THE HOTCUPBOARD ATTACHMENT REQUIRES A INDEPENDENT SINGLE PHASE
SUPPLY.
WARNING: THIS APPLIANCE MUST BE EARTHED.
THIS APPLIANCE IS DESIGNED FOR THE VOLTAGE STATED ON THE RATING PLATE,
WHICH IS SITUATED ON A SLIDE-OUT TRAY IN THE HOT CUPBOARD BASE PLATE
ABOVE THE PLINTH.
IF THE SUPPLY CORD IS DAMAGED, IT MUST BE REPLACED BY THE MANUFACTURER,
ITS SERVICE AGENT OR SIMILARLY QUALIFIED PERSON TO AVOID A HAZARD.
A 230v ~ 50 Hz, 3 amp fused electrical supply is required adjacent to the appliance (with the
exception of the AGA TC5 and DC5 Hotcupboard with Induction Hob model, please refer to the
AGA Induction Hob model instructions for the power supply requirements). External wiring to the
unit must be installed using the mains cable provided, in accordance with the current regulations
and any local regulations which apply.
The method of connection to the mains electricity supply must facilitate complete electrical
isolation of the appliance, preferably by a fused double pole switch, having a contact separation
of at least 3mm in both poles.
The isolator should not be positioned immediately above the hotcupboard, but must be fitted
within 2 metres of the appliance.
7