Advertisement

Quick Links

AGA TOTAL CONTROL
TC3G & TC5G

Installation Instructions

CAUTION: THIS UNIT IS HEAVY, PROPER EQUIPMENT AND ADEQUATE MANPOWER MUST BE USED IN MOVING THE
RANGE TO AVOID DAMAGE TO THE UNIT OR THE FLOOR.
REMEMBER, when replacing a part on this appliance, use only spare parts that you can be assured conform to the safety and
performance specification that we require.
DO NOT use reconditioned or copy parts that have not been clearly authorised by AGA.
PLEASE READ THESE INSTRUCTIONS BEFORE USING THIS APPLIANCE
AND KEEP IN A SAFE PLACE FOR FUTURE REFERENCE.
For use in GB & IE
11/16 EINS 516350

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TC3G and is the answer not in the manual?

Questions and answers

Summary of Contents for AGA TC3G

  • Page 1: Installation Instructions

    REMEMBER, when replacing a part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification that we require. DO NOT use reconditioned or copy parts that have not been clearly authorised by AGA. PLEASE READ THESE INSTRUCTIONS BEFORE USING THIS APPLIANCE AND KEEP IN A SAFE PLACE FOR FUTURE REFERENCE.
  • Page 2 Make a note of your AGA Total Control Serial Number when it is being installed. The serial number can be found behind the magnetic plinth cover. My AGA Details: Serial No: AGA Service No: Date of Installation: Data badge located...
  • Page 3: Table Of Contents

    Contents Health and Safety Introduction Location Specifications Power Supply Hotcupboard TC5 Vent Vent Pipe Connection Oven Venting System Fig. 5.2 Hotcupboard Installation Circuit Diagram AGA TC3 Circuit Diagram AGA TC5 Checklist 10. Servicing...
  • Page 5: Health And Safety

    Health and Safety Consumer Protection The appliance may contain some of the materials that are indicated below. It is the Users/Installers responsibility to As a responsible manufacturer, we take care to make sure ensure that the necessary personal protective clothing that our products are designed and constructed to meet the is worn when handling where applicable, the pertinent required safety standards when properly installed and used.
  • Page 6 Deep Fat Frying If You Smell Gas • Use a deep pan, large enough to completely cover the • DO NOT turn electric switches on or off appropriate heating area. • DO NOT smoke NEVER fill the pan more than one-third full of fat or •...
  • Page 7: Introduction

    1005mm x 740mm could be With specific exceptions, the installing of any type of AGA used to check if the AGA Total Control fully built appliance is cooker is subject to the respective directions contained in able to fit through the property grounds and doors into its the current issue of the Building Regulations.
  • Page 8: Location

    Surfaces over the top of the cooker must not be closer than If the AGA is to be installed in a brick recess, then the 650 mm. minimum clearance should be increased by at least 10 mm, to The vent slots in the back of the top plate (or shroud) must allow for the walls not being square.
  • Page 9: Specifications

    10 mm beyond the figures quote above. This allows safe margin to take into account the natural dimensional variations found in major castings in particular the width across an appliance recess could be critical. APPLIANCE WEIGHT (Excludes Packaging) Model: AGA Total Control (TC3) - 370kg...
  • Page 10 10mm beyond the figures quote above. This allows safe margin to take into account the natural dimensional variations found in major castings in particular the width across an appliance recess could be critical. APPLIANCE WEIGHT (Excludes Packaging) Model: AGA Total Control (TC3) - 370kg Hotcupboard: 110kg...
  • Page 11: Power Supply

    Power Supply Fig. 4.1 WARNING: THIS APPLIANCE MUST BE EARTHED. THIS APPLIANCE IS DESIGNED FOR THE VOLTAGE STATED ON THE RATING PLATE, WHICH IS SITUATED BEHIND THE PLINTH COVER. If the supply cord is damaged, it must be replaced Mains cable fed from control by the manufacturer, its service agent or similarly tray left or right exit through qualified person to avoid a hazard.
  • Page 12: Hotcupboard Tc5

    Hotcupboard TC5 Fig. 4.3 DESN 516446 THE HOTCUPBOARD ATTACHMENT REQUIRES A INDEPEDENT SINGLE PHASE POWER SUPPLY. WARNING: THIS APPLIANCE MUST BE EARTHED. THIS APPLIANCE IS DESIGNED FOR THE Hotcupboard VOLTAGE STATED ON THE RATING PLATE, Power Supply WHICH IS SITUATED ON A SLIDE-OUT TRAY IN THE HOTCUPBOARD BASE PLATE ABOVE THE PLINTH.
  • Page 13: Vent

    Reseal pipe connection with aluminium tape. When installing a AGA TC5 which is venting to the left hand side, care must always be taken to ensure the vent pipe is fully lagged (using insulation provided). Where the vent pipe passes behind the hotcupboard, ensure that the mains cable is kept away from the hot surface of the vent pipe.
  • Page 14: Oven Venting System Fig

    Oven Venting System Fig. 5.2 Fig. 5.2 DESN 516111 The appliance oven venting pipe can be achieved up to a maximum length of 6 metres, through an outside wall. Great care must be taken in all-timber houses. If the oven vent pipe passes through combustible material, there must be an air gap of at least 25mm around the pipe and preferably wrapped with insulation material.
  • Page 15: Hotcupboard Installation

    Fig. 6.1 plate in a jacked up position. This is to allow the complete appliance to be slid onto its plinth when alongside the AGA TC3 without the top plates clashing. The hotcupboard top plate should then be wound down to its correct height once the appliance is in its final position.
  • Page 16 AGA TC3 plinth. Run a straight edge along the front of the AGA Total Control plinth, to ensure the front face of both plinths sit squarely against the straight edge (Fig. 6.5). When...
  • Page 17 AGA TC3 (Fig. 6.9). For servicing requirement, top plate should be removed by...
  • Page 18 Slide the complete handrail assembly over the left hand Fig. 6.10 and centre fixing studs. Once the assembly has been fitted to the AGA appliance, fit the handrail endcaps (ensuring the handrail is evenly spaced at each end). The endcaps should be carefully pushed into place until they sit flush with the outside face of each bracket.
  • Page 19: Circuit Diagram Aga Tc3

    Circuit Diagram AGA TC3...
  • Page 20: Circuit Diagram Aga Tc5

    Circuit Diagram AGA TC5 CAUTION: label all wires prior to disconnection, when servicing controls wiring errors can cause improper and dangerous operation. Verify proper operation after servicing DESN 517488 Code Colour Blue Brown Black Orange Green...
  • Page 21: Checklist

    9. Checklist Hand these instructions to the user for retention, and instruct in the safe operation of the appliance. Tick Box / Not Serial No. Applicable (N/A) Check hotplate lids and settings. Check oven door seals, adjust door alignment if necessary. Baking and Simmering oven rope seals MUST have a gap between the door hinges.
  • Page 22 After 1 hour, check oven and hotplate thermocouple temperatures using Engineers Handset (approx.). Hotspot (330 - 380°C) Simmerspot (200 - 250°C) Roasting Oven (235 - 245°C) Baking Oven (180 - 185°C) Simmering Oven (95 - 115°C) During warm-up period, check customer’s handset handshakes and instruct customer on it’s application and operation.
  • Page 23: Servicing

    AGA tor an authorised distributor. • DO NOT alter or modify the cooker. Spare Parts To maintain optimum and safe performance, we recommend that only genuine AGA spare parts are used. These are available from most major spares stockists, including ourselves.
  • Page 24 For further advice or information contact your local AGA Specialist. With AGA Rangemaster’s policy of continuous product improvement, the Company reserves the right to change specifications and make modifications to the appliances described and illustrated at any time. Manufactured By...

This manual is also suitable for:

Tc5g

Table of Contents