6.1.2. Connecting AC power

AC24V
AC24V
6.2. Connecting & Setting serial port

6.2.1. Connecting RS232

Within WebEye B101, there are four RS232 communication terminals; RX1, TX1, RX2, and TX2.
When connecting RX1, and TX1, connect each pin to No. 1~3 hole. And when connecting, RX2,
TX2, connect each pin to No. 3~5 hole.
RX1
TX1
GND

6.2.2. Connecting RS422

Connect each pin to No. 6~9(R+, R-, T+, T-) hole.

6.2.3. Connecting RS485

Connect each pin to No. 6~7(S+, S-) hole.