Mains Connection; Operation; Switch On The Machine; Setting Cleaning Temperature - Kärcher HDS Super SX Operating Instructions Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 21
Operating Instructions

Mains connection

Refer to technical data and rating plate for
connected loads.
Warning!
Whenever socket is changed, check
direction of rotation of motor
— If direction of rotation is correct, powerful
jet of air will be felt at exhaust-gas
opening of burner.
— If direction of rotation is wrong:
interchange terminals at unit plug. See
Figure 17.
! When an extension cable is used it
should always be complety unwound
and have an adequate cross-section.

Operation

Warning! (Only HDS Super SX)
Lengthy operation of the unit can lead to
vibration-related circulatory disturbances of
the hands.
It is not possible to specify a generally
applicable use duration, since this is
dependent and influenced by a number of
factors:
— Personal predisposition to bad
circulation (frequent suffering from cold
fingers, pins and needles in fingers).
— In low ambient temperatures. Wear
warm gloves to keep hands warm.
— Gripping tightly impedes circulation.
— Continuous operation is more
detrimental than operation interrupted by
breaks.
We recommend a medical examination if
the unit is regularly used for extensive,
continuous operation and the
corresponding symptoms (such as, for
example, pins and needles in fingers or
cold fingers) are recurrent.
HDS Super SX/HDS 695 SX/HDS 895 SX/HDS 1195 SX

Switch on the machine

! Set the unit switch (item 23) to "I"
Ready for working indicator lamp (item28)
is lit
Warning!
The temperature regulator (item 24) must
be at setting "0", since it is otherwise
possible that the burner switches itself on
Unit starts up briefly and is switched off as
soon as operating pressure is reached.
Shut down unit immediately if indicator
lamp (item25-27) lights up during operation.
Eliminate fault, refer to Faults.
Figure 9
! Release handgun
Actuation of handgun switches unit back on
again.
Bleed pump if no water emerges from high-
pressure nozzle. Refer to Faults "No build-
up of pressure by unit"

Setting cleaning temperature

! Set the temperature regulator (item 24)
to the required temperature
30°C to 90°C
Hot water cleaning
100°C to 150°C
Clean with steam, with steam nozzle
- 4.766-023 (HDS Super SX /
HDS 695 SX / HDS 895 SX)
- 4.766-024 (HDS 1195 SX)