Adjustments And Servicing Procedures; Adjustment Of The Continuous Regulating System - Atlas Copco XAHS 37 DD Instruction Manual

Portable
Table of Contents

Advertisement

Instruction Manual
5.

ADJUSTMENTS AND SERVICING PROCEDURES

5.1
A
DJUSTMENT OF THE CONTINUOUS REGULATING SYSTEM
Without generator
Fig. 5.1
The working pressure is determined by the tension of the spring in
the regulating valve (RV). This tension can be increased to raise the
pressure and decreased to lower it by turning the adjusting wheel
clockwise and anti-clockwise respectively.
To adjust the normal working pressure, proceed as follows:
1. Start and warm up the engine (see section 3.2).
2. With the outlet valves (AOV) closed, pull out the knob, adjust the
regulating valve (RV) until a pressure of X bar(e) is reached (see
table).
3. Check the minimum speed of the engine. Adjust minimum speed
stop screw if necessary.
4. Open an outlet valve (AOV) just enough to let the engine (E) run
at maximum speed. The working pressure must be Y bar(e) (see
table); adjust if necessary with regulating valve (RV).
5. Check the engine maximum speed. Adjust the maximum speed
by means of adjusting eccentric nut on top of speed regulator
(SR).
6. Close the outlet valves (AOV), check that the pressure is between
Z1 and Z2 bar(e) (see table). Lock the regulating valve (RV) by
pushing the knob down.
7. Check the operation of the solenoid valve (SV
with a generator.
Table
XAHS 37 DD -
XAHS 70 DD7
) when equipped
SR
XAS 47 DD -
XAS 90 DD7
XAS 57 DD -
XAS 110 DD7
With generator
X
Y
bar(e)
bar(e)
13.5
12
8.5
7
8.5
7
Z1 – Z2
bar(e) bar(e)
13.3 – 13.7
8.3 – 8.7
8.3 – 8.7
47

Hide quick links:

Advertisement

Table of Contents
loading