3.2.3 S
TARTING PROCEDURE
P1
Hourmeter
F1
Circuit breaker button
PG
Working pressure gauge
H1
Temperature alarm lamp (red)
H2
General alarm lamp (red)
S1
Start switch
S4
Lamp test button
Fig. 3.15
Control panel (without cold start)
The control panel indicates receiver pressure (PG) and
accumulated operating hours (P1).
Before starting open the air outlet valve(s)
circuit breaker button (F1) once (open hood first).
A
Fig. 3.16
Positions of circuit breaker button
Circuit breaker button should now be in position B.
The circuit breaker button is a protection against
unintended starting of the compressor.
Fig. 3.17
Starting procedure
1. To start, turn start switch S1 clockwise to position 1, lamp H2
(general alarm lamp) will go on.
2. Check correct operation of alarm lamps H1 and H2 by pushing
lamp test button S4. Both alarm lamps (red) should go on.
3. Turn start switch S1 further clockwise into position 3.
The starter motor will set the engine in motion.
The maximum allowed starter time, where the starter motor is
running continuously is 20 seconds.
If the engine does not catch, a new attempt can be made after 30
seconds waiting.
The temperature alarm lamp H1 and the general alarm lamp H2
will go out as soon as the engine has been started.
36
(
WITHOUT COLD START
P1
PG
(Fig.
2.3, AOV) and push
B
)
S1
H1
F1
0
1
2 3
H2
4. The start switch automatically springs back to position 1.
Lamp H1 only will go on when the compressor outlet
temperature is too high.
5. Close the air outlet valve(s)
Instruction Manual
S4
(Fig.
2.3, AOV).