Download Print this page

Control Operation - Nilfisk-ALTO POSEIDON 3 Operating Instructions Manual

Hide thumbs Also See for POSEIDON 3:

Advertisement

POSEIDON 3
Spray Jet Devices". The high-
pressure cleaner must be sub-
jected to a safety examination
in accordance with the „Acci-
dent Prevention Regulations for
Working with Liquid Spray Jet
Devices (BGV A3)" as required,
but at least every 12 months, by
an authorised inspector.
After all repairs or modifica-
tions to electrical equipment,
the protective conductor resist-
ance, the insulation resistance
and the leakage current must
be measured. Furthermore, a
visual inspection of the mains
power lead, a voltage and cur-
rent measurement and a func-
tion test must be carried out. Our
after-sales service technicians
are at your disposal as author-
ised inspectors.
Description
Purpose
Control / Operation
Operating elements
Using cleaning agents
10
The complete „Accident Preven-
tion Regulations for Working
with Liquid Spray Jet Devices"
are available from the Carl Hey-
manns Verlag KG, Luxemburger
Strasse 449, 50939 Cologne
or from the appropriate asso-
ciation of employers' liability
insurances.w
Unloader valve
Unacceptably high pressure is
fed back without residual pres-
sure via a bypass line into the
intake line of the pump when the
safety device is tripped.
The unloader valve is set and
sealed at the factory and must
not be adjusted.
Safety devices
Locking device on spray gun:
The spray gun features a locking
device. When the pawl is acti-
vated, the spray gun cannot be
ope rated.
This high-pressure cleaner has
been designed for professional
use in
– Agriculture
– industry
– transport industry
– automotive cleaning
– municipal facilities
1 Spray gun
2 Mains power lead
3 Spray lance
4 Receptacle for electrical
lead
5 Detergent intake hose
6 Detergent metering knob
Cleaning agent can be drawn
in via the injector installed as
standard only in low-pressure
mode.
1)
Model variants
O
Ther mal overcurren circuit
breaker:
A thermal current sensor pro-
tects the motor against overload-
ing. The machine will restart after
a few minutes when the thermal
sensor has cooled.
Warning
Inhalation of aerosols can
be hazardous to health.
Where applicable use a de-
vice in order to avoid or re-
duce aerosols production,
e.g., a shield covering the
nozzle.
For protection against aero-
sols use a respiratory mask
of class FFP 2 or higher.
– cleaning trade
– construction industry
– food industry
etc.
Always use the cleaner as de-
scribed in these operating in-
structions. Any other use may
damage the cleaner or the sur-
face to be cleaned or may result
in severe injury to persons.
7 Receptacle for Spray lance
8 Supply water connection with
water inlet filter
9 High pressure hose connection
10 Main switch
11 Handle
1)
12 Hose reel
CAUTION!
Never allow cleaning agent to
dry on the surface to be cleaned.
The surface may be damaged.
Original Operating Instructions