Advertisement

Operating instructions

POSEIDON 5-6-7
107141543 D - EN DE FR NL

Advertisement

Table of Contents
loading

Summary of Contents for Nilfisk-ALTO POSEIDON 5

  • Page 1: Operating Instructions

    Operating instructions POSEIDON 5-6-7 107141543 D - EN DE FR NL...
  • Page 2 English ............................ 3 Deutsch ..........................34 Français ..........................66 Nederlands ........................... 98...
  • Page 3: Table Of Contents

    POSEIDON 5-6-7 Contents Symbols used to mark instructions .....................4 Important safety instructions ...................4 Description.........................7 Use per day ..........................7 Purpose ...........................7 Operating elements .........................8 Before starting the cleaner ....................9 Setting up the cleaner ......................9 Check the oil level ........................9 Fill up detergent tank ......................10 Connecting the high pressure hose ..................10...
  • Page 4: Symbols Used To Mark Instructions

    POSEIDON 5-6-7 Symbols used to mark instructions Safety instructions in these This indicates tips and instruc- operating instructions which tions to simplify work and to en- must be observed to prevent sure safe operation. risks to persons are marked with this danger symbol.
  • Page 5 POSEIDON 5-6-7 CAUTION! NOTE! reels completely to prevent the High-pressure water jets can be maximum permissible power cord overheating. dangerous if misused. The jet working pressure and tempera- must not be directed at persons, ture are printed on the high-...
  • Page 6 Please contact the Nilfisk-ALTO Safety devices service department or an au- Thermal sensor: thorised specialist work-shop for...
  • Page 7: Description

    POSEIDON 5-6-7 2 Description Use per day We recommend these products for an optional use of approx. X-hours use per day. POSEIDON 5 Hours use per day Recommended for use x hours / day POSEIDON 6 Hours use per day...
  • Page 8: Operating Elements

    POSEIDON 5-6-7 Operating elements 1. Push/pull handle 2. Spray gun 3. Electrical lead 4. Holder for high pressure hose 5. High-pressure hose 6. Fastening screw 7. Lance 8. Parking brake 9. High-pressure hose connection (on standard models without hose reel) 10.
  • Page 9: Before Starting The Cleaner

    POSEIDON 5-6-7 3 Before starting the cleaner Setting up the cleaner CAUTION! Never lift the cleaner alone. Always ask a second person to help. 1. Before using the cleaner for the first time, check it care- fully to detect any faults or damage.
  • Page 10: Fill Up Detergent Tank

    POSEIDON 5-6-7 Fill up detergent tank 1. Fill up detergent tank with prediluted Nilfisk-ALTO de- tergent. 2. Pull detergent hose and filter out of the storage and put it through the opening of the detergent tank filler cap. Connecting the high 1.
  • Page 11: Electrical Connection

    POSEIDON 5-6-7 NOTE! In the case of poor water quality We recommend the use of a tex- (sand, etc.), we recommend that tile-reinforced water hose with a a fine water filter is fitted to the nominal diameter of min. 3/4"...
  • Page 12: Ba Valve

    POSEIDON 5-6-7 BA valve This high pressure washer/cleaner is only allowed to be con- nected with the drinking water mains, when an appropriate backflow preventer has been installed, Type BA according to EN 60335-2-79. The BA valve can be ordered under number: (a) Female •...
  • Page 13: Control / Operation

    POSEIDON 5-6-7 4 Control / Operation Connecting the spray 1. Pull back the blue quick- lance to the spray gun release grip (A) of the spray gun. 2. Insert the nipple of the spray lance (B) into the quick- release connection and re- lease the coupling (A).
  • Page 14 POSEIDON 5-6-7 4.2.1 Switching on the 1. Before connecting the cleaner when it is suction set: 61256 to the connected to open cleaner, fill the hose with tanks in suction mode water. (Pressure activated model) 2. Turn the main switch to posi tion "...
  • Page 15: Pressure Regulation With Tornado Plus Lance And Powerspeedvario Plus Lance

    POSEIDON 5-6-7 Pressure regulation 1. Turn the twist grip on the with Tornado Plus lance: lance and PowerSpeedVario Plus – High pressure = lance. clockwise (+) – Low pressure = anticlockwise (–) 1. Twist cap of the FlexoPower- Pressure Plus nozzle head:...
  • Page 16: Lifting With Crane

    POSEIDON 5-6-7 Lifting with crane 1. Before crane lifting the machine should be in balance. Loosen the screw (A), push the handle (B) a little forward. 2. When the two marks are aligned (C), the handle is in crane-lifting -position.
  • Page 17: Applications And Methods

    POSEIDON 5-6-7 5 Applications and methods Techniques Efficient high pressure cleaning is achieved by following a few guidelines, combined with your own personal experience of specific cleaning tasks. Accessories and detergents, when correctly chosen, can increase the efficiency of your pressure washer. Here is some basic information about cleaning.
  • Page 18: Some Typical Cleaning Tasks

    POSEIDON 5-6-7 Some typical cleaning tasks 5.2.1 Agriculture Task Accessories Method Stables Chemical Foam 1. Soaking – apply foam to all surfaces (bottom to top) Pig Pens, Sties Injectors and wait for approx. 10 - 30 minutes. Foam lance 2. Remove the dirt from surfaces with the high...
  • Page 19 POSEIDON 5-6-7 5.2.3 Buildings and Equipment Task Accessories Method General surfaces Foam injectors 1. Apply thick foam over the surfaces to be cleaned. Standard lance Apply on dry surfaces. Apply from top to bottom on Metallic equipment Curved lances vertical surfaces. Let the foam act for up to 10 - 30 Tank cleaning minutes for the optimal effect.
  • Page 20: After Using The Cleaner

    POSEIDON 5-6-7 6 After using the cleaner Switching off the 1. Turn the main switch to posi- cleaner tion „OFF“. 2. Close water tap. 3. Squeeze the spray gun han- dle until the cleaner is de- pressurised. 4. Lock the safety catch on the spray gun.
  • Page 21: Storing The Cleaner (Below 0°C)

    POSEIDON 5-6-7 2. At last turn, lock the cable end in the cable lock (C). Storing the cleaner Store the cleaner in a dry room without danger of frost or protect as (below 0°C) below: CAUTION! If the high-pressure cleaner is stored in a room with temperatures ...
  • Page 22: Maintenance

    POSEIDON 5-6-7 7 Maintenance Maintenance plan First time Every 500 after 50 Weekly operating As required operating hours hours   7.2.1 Cleaning water inlet fi lter  7.2.2 Checking pump oil level  7.2.3 Changing pump oil First change - and ...
  • Page 23 POSEIDON 5-6-7 2. If necessary, add oil. Fill to MAX level (B). 7.2.3 Changing the pump oil 1. Before changing the oil, al- low the cleaner to become warm. 2. Remove cabinet. 3. Loosen and remove drain plug (C).The plug magnet has...
  • Page 24: Troubleshooting

    POSEIDON 5-6-7 8 Troubleshooting Fault Cause Remedy Pressure drop • Air in the system • Vent the system by operating the spray gun several times at short intervals. If necessary, operate the cleaner for a short time without the high- pressure hose connected.
  • Page 25: Further Information

    POSEIDON 5-6-7 Fault Cause Remedy No detergents drawn in • Detergent tank empty • Top up detergent tank • The cap on the FlexoPower- • Set to low pressure Plus nozzle head is not set to low pressure • Double lance are not adju- •...
  • Page 26: Technical Data

    POSEIDON 5-6-7 Technical Data Options / model variants Original instructions...
  • Page 27 POSEIDON 5-6-7 Options / model variants Original instructions...
  • Page 28 POSEIDON 5-6-7 Options / model variants Original instructions...
  • Page 29 POSEIDON 5-6-7 Options / model variants Original instructions...
  • Page 30 POSEIDON 5-6-7 Options / model variants Original instructions...
  • Page 31 POSEIDON 5-6-7 Options / model variants Original instructions...
  • Page 32 POSEIDON 5-6-7 Options / model variants Original instructions...
  • Page 33 POSEIDON 5-6-7 Options / model variants Original instructions...
  • Page 34 HEAD QUARTER HOLLAND PORTUGAL DENMARK Nilfi sk-Advance B.V. Nilfi sk-Advance, Lda. Nilfi sk-Advance A/S Versterkerstraat 5 Sintra Business Park Sognevej 25 1322 AN ALMERE Zona Industrial Da Abrunheira DK-2605 Brøndby www.nilfi sk.nl Edifi cio 1, 1o A Tel.: (+45) 4323 8100 Sintra, P-2710-089 www.nilfi...

This manual is also suitable for:

Poseidon 6Poseidon 7

Table of Contents