Parameters Example:
The following is a typical list of parameter changes that may be needed in addition to the factory default settings
(P204=5).
P000=5
P204=5
P100=5
P101=10
P133=3.00
P134=60.00
Local/Remote parameters allow the drive to be set up to operate from Keypad, Remote Terminal, or a
programmed combination of keypad and terminal inputs.
P221 – Local Speed Reference Selection
P222 – Remote Speed Reference Selection
P229 – Local Command Selection
P230 – Remote Command Selection
P231 – Forward/Reverse Selection
Read Only Parameters (P002 – P040) can be used for monitoring and troubleshooting. For a full list and
description please read the CFW10 User's Guide. By monitoring certain read only parameters, drive operational
values can be determined without the use of any other test equipment.
P002 – Frequency Proportional Value (Speed)
P003 – Motor Current
P004 – used to monitor DC Link Voltage.
P005 – Motor Frequency
P007 – Motor Output Voltage
P014 – Last fault
These are just a few examples of drive set-up and parameters. Please read the CFW10 User's Guide for additional
information.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Parameter Access (5 = Password)
Loads Factory Default
Acceleration Time = 5 seconds
Deceleration Time = 10 seconds
Minimum Frequency = 3.00 Hz
Maximum Frequency – 60.00 Hz