INSTALLATION
1. Lift the Secure Router 3120 assembly into the rack and align the bracket holes with
2. Attach the Secure Router 3120 to the rack according to the instructions provided
Figure 5: Rackmounting the Secure Router 3120

Secure Router 3120 Power

The Avaya 3120 supports single AC, dual AC, single DC, dual DC or AC/DC power, depending
on the ordered configuration. These Secure Router 3120s accept external power from single
AC, dual AC, single DC, dual DC, or single AC/single DC sources. External 48 volt DC power
supplies are not provided by Avaya and must be obtained from a third-party vendor.

DC Power

Up to two external DC power supplies can be connected to the terminal block on the back
panel of these Secure Router 3120s.
Electrostatic alert:
ESD
Before connecting cables or performing maintenance on a Secure Router 3120, always wear
an ESD-preventative wrist strap. Connect the banana plug to the ESD ground connector on
the Secure Router 3120 chassis. Make sure that the wrist strap makes contact with your skin.
30
Avaya Secure Router 3120 Installation Guide
the desired holes on the rack.
Caution:
Practice good safety habits. Use two people to rackmount the Secure Router
3120.
by the rack manufacturer.