Defaults
By default, administrative egress is set to untagged.
Mode
Switch command, read‐write.
Example
This example shows how to enable the insertion of the RADIUS assigned VLAN to an 802.1q tag
for all outbound frames for ports 10 through 15 on unit/module number 3.
B5(rw)->set vlanauthorization egress tagged ge.3.10-15
clear vlanauthorization
Use this command to return port(s) to the default configuration of VLAN authorization disabled,
egress untagged.
Syntax
clear vlanauthorization [port-string]
Parameters
port‐string
Defaults
If no port string is entered, all ports a will be reset to default configuration with VLAN
authorization disabled and egress frames untagged.
Mode
Switch command, read‐write.
Example
This example show how to clear VLAN authorization for all ports on slots 3, 4, and 5:
B5(rw)->clear vlanauthorization ge.3-5.*
show vlanauthorization
Displays the VLAN authentication status and configuration information for the specified ports.
Syntax
show vlanauthorization [port-string]
(Optional) Specifies which ports are to be restored to default
configuration. If no port string is entered, the action will be a global
setting. For a detailed description of possible port‐string values, refer to
"Port String Syntax Used in the CLI" on page 7‐1.
clear vlanauthorization
Enterasys B5 CLI Reference 22-51