General Description
2.2
Heat exchanger
The heat generated by combustion in the heat exchanger is
given off to the cold air transported by the heating air fan.
Fig. 204
Heat exchanger
2.3
Evaporator mount with combustion
pipe
The fuel is distributed via the metal fibre evaporator (fleece)
in the evaporator mount. The mixture of fuel and air burns in
the combustion chamber, thus causing the heat exchanger to
become hot.
Fig. 205
Evaporator mount (diesel) and combustion
pipe
202
Visit www.butlertechnik.com for more technical information and downloads.
www.butlertechnik.com
Air Top Evo 40 / Air Top Evo 55
Fig. 206
Evaporator mount (petrol) and combustion
pipe
2.4
Glow plug
The mixture of fuel and air is ignited by the glow plug when
the heater is started. The glow plug designed as an electrical
resistor is positioned in the burner assembly (evaporator
mount with combustion pipe) on the side facing the flame.
Fig. 207
Glow plug