Summary of Contents for Supermicro SC504-203B

  • Page 1 UPER ® SC504 Chassis Series SC504-203B USER’S MANUAL...
  • Page 2 This product, including software and documentation, is the property of Supermicro and/or its licensors, and is supplied only under a license. Any use or reproduction of this product is not allowed, except as expressly permitted by the terms of said license.
  • Page 3: About This Manual

    SC504 chassis. Installation and maintenance should be performed by experienced technicians only. Supermicro’s SC504 chassis features a unique and highly-optimized design for low wattage processor platforms. The chassis is equipped with a 200W power supply.
  • Page 4: Manual Organization

    SC504 Chassis Manual Manual Organization Chapter 1 Introduction The first chapter provides an overview the main components included with this chassis and describes the main features of the SC504 chassis. This chapter also includes contact information. Chapter 2 System Safety This chapter lists warnings, precautions, and system safety.
  • Page 5: Table Of Contents

    Overview ......................1-1 Shipping List ....................1-1 Part Numbers ....................1-1 Where to get Replacement Components ............1-2 Contacting Supermicro ..................1-3 Chapter 2 Standardized Warning Statements for AC Systems About Standardized Warning Statements ............2-1 Warning Definition ................... 2-1 Installation Instructions ..................
  • Page 6 Installing the Motherboard ................5-6 Chassis Standoffs ................... 5-6 Motherboard Installation .................. 5-6 Installing the Expansion Card ................. 5-7 Installing Optional System Fans ..............5-9 Checking the Chassis Airflow................ 5-10 Power Supply ....................5-11 Replacing the Power Supply ................5-11 Chapter 6 Rack Installation Overview ......................
  • Page 7: Chapter 1 Introduction

    SC504-200B chassis is equipped with a high-efficiency 80%+ low noise power supply. Shipping List Part Numbers Please visit the Supermicro Web site for the latest shiping lists and part numbers for your particular chassis model http://www.supermicro.com/ SC504-200B Chassis Power Model...
  • Page 8: Where To Get Replacement Components

    Infrequently, you may need replacement parts for your system. To ensure the highest level of professional service and technical support, we strongly recommend pur- chasing exclusively from our Supermicro Authorized Distributors/System Integrators/ Resellers. A list of Supermicro Authorized Distributors/System Integrators/Resellers can be found at: http://www.supermicro.com. Click the Where to Buy link.
  • Page 9: Contacting Supermicro

    Super Micro Computer, Inc. 980 Rock Ave. San Jose, CA 95131 U.S.A. Tel: +1 (408) 503-8000 Fax: +1 (408) 503-8008 Email: marketing@supermicro.com (General Information) support@supermicro.com (Technical Support) Web Site: www.supermicro.com Europe Address: Super Micro Computer B.V. Het Sterrenbeeld 28, 5215 ML...
  • Page 10 SC504 Chassis Manual Notes...
  • Page 11: Chapter 2 Standardized Warning Statements For Ac Systems

    Only certified technicians should attempt to install or configure components. Read this appendix in its entirety before installing or configuring components in the Supermicro chassis. These warnings may also be found on our web site at http://www.supermicro. com/about/policies/safety_information.cfm. Warning Definition Warning! This warning symbol means danger.
  • Page 12 UPER ERVER "servername" User's Manual Warnung WICHTIGE SICHERHEITSHINWEISE Dieses Warnsymbol bedeutet Gefahr. Sie befinden sich in einer Situation, die zu Verletzungen führen kann. Machen Sie sich vor der Arbeit mit Geräten mit den Gefahren elektrischer Schaltungen und den üblichen Verfahren zur Vorbeugung vor Unfällen vertraut.
  • Page 13 Warning Statements for AC Systems ‫جسذٌة‬ ‫اصابة‬ ً‫تتسبب ف‬ ‫حالة ٌوكي أى‬ ً‫اًك ف‬ ‫خطز‬ ًٌ‫ٌع‬ ‫هذا الزهز‬ !‫تحذٌز‬ ‫الذوائز‬ ‫بالوخاطز الٌاجوة عي‬ ‫ي على علن‬ ، ‫ك‬ ‫هعذات‬ ‫تعول على أي‬ ‫قبل أى‬ ‫الكهزبائٍة‬ ‫حىادث‬ ‫أي‬ ‫وقىع‬ ‫وٌع‬ ‫ل‬ ‫الىقائٍة‬...
  • Page 14: Installation Instructions

    UPER ERVER "servername" User's Manual Installation Instructions Warning! Read the installation instructions before connecting the system to the power source. 設置手順書 システムを電源に接続する前に、 設置手順書をお読み下さい。 Warnung Vor dem Anschließen des Systems an die Stromquelle die Installationsanweisungen lesen. ¡Advertencia! Lea las instrucciones de instalación antes de conectar el sistema a la red de alimentación.
  • Page 15: Circuit Breaker

    Chapter 4: Warning Statements for AC Systems Circuit Breaker Warning! This product relies on the building's installation for short-circuit (overcurrent) protection. Ensure that the protective device is rated not greater than: 250 V, 20 A. サーキッ ト ・ ブレーカー この製品は、 短絡 (過電流) 保護装置がある建物での設置を前提としています。 保護装置の定格が250 V、...
  • Page 16: Power Disconnection Warning

    UPER ERVER "servername" User's Manual 경고! 이 제품은 전원의 단락(과전류)방지에 대해서 전적으로 건물의 관련 설비에 의존합니다. 보호장치의 정격이 반드시 250V(볼트), 20A(암페어)를 초과하지 않도록 해야 합니다. Waarschuwing Dit product is afhankelijk van de kortsluitbeveiliging (overspanning) van uw electrische installatie. Controleer of het beveiligde aparaat niet groter gedimensioneerd is dan 220V,20A.
  • Page 17 Chapter 4: Warning Statements for AC Systems Le système doit être débranché de toutes les sources de puissance ainsi que de son cordon d'alimentation secteur avant d'accéder à l'intérieur du chassis pour ‫אזהרה מפני ניתוק חשמלי‬ installer ou enlever des composants de systéme. !‫אזהרה‬...
  • Page 18: Equipment Installation

    UPER ERVER "servername" User's Manual Equipment Installation Warning! Only trained and qualified personnel should be allowed to install, replace, or service this equipment. 機器の設置 トレーニングを受け認定された人だけがこの装置の設置、 交換、 またはサービスを許可 されています。 Warnung Das Installieren, Ersetzen oder Bedienen dieser Ausrüstung sollte nur geschultem, qualifiziertem Personal gestattet werden. ¡Advertencia! Solamente el personal calificado debe instalar, reemplazar o utilizar este equipo.
  • Page 19: Restricted Area

    Chapter 4: Warning Statements for AC Systems Waarschuwing Deze apparatuur mag alleen worden geïnstalleerd, vervangen of hersteld door geschoold en gekwalificeerd personeel. Restricted Area Warning! This unit is intended for installation in restricted access areas. A restricted access area can be accessed only through the use of a special tool, lock and key, or other means of security.
  • Page 20: Battery Handling

    UPER ERVER "servername" User's Manual ‫אזור עם גישה מוגבלת‬ !‫אזהרה‬ ‫יש להתקין את היחידה באזורים שיש בהם הגבלת גישה. הגישה ניתנת בעזרת‬ .)'‫כלי אבטחה בלבד (מפתח, מנעול וכד‬ ‫محظورة‬ ‫مناطق‬ ٍ‫نتركُبها ف‬ ‫هذه انىحذة‬ ‫تخصيص‬ ‫تم‬ ،‫أداة خاصت‬ ‫من خالل استخذاو‬ ‫فقط‬...
  • Page 21 Chapter 4: Warning Statements for AC Systems Warnung Bei Einsetzen einer falschen Batterie besteht Explosionsgefahr. Ersetzen Sie die Batterie nur durch den gleichen oder vom Hersteller empfohlenen Batterietyp. Entsorgen Sie die benutzten Batterien nach den Anweisungen des Herstellers. Attention Danger d'explosion si la pile n'est pas remplacée correctement. Ne la remplacer que par une pile de type semblable ou équivalent, recommandée par le fabricant.
  • Page 22: Redundant Power Supplies

    UPER ERVER "servername" User's Manual Redundant Power Supplies Warning! This unit might have more than one power supply connection. All connections must be removed to de-energize the unit. 冗長電源装置 このユニッ トは複数の電源装置が接続されている場合があります。 ユニッ トの電源を切るためには、 すべての接続を取り外さなければなりません。 Warnung Dieses Gerät kann mehr als eine Stromzufuhr haben. Um sicherzustellen, dass der Einheit kein trom zugeführt wird, müssen alle Verbindungen entfernt werden.
  • Page 23: Backplane Voltage

    Chapter 4: Warning Statements for AC Systems ‫امداد الطاقة‬ ‫بوحدات‬ ‫عدة اتصاالت‬ ‫جهاز‬ ‫ال‬ ‫يكون لهذا‬ ‫قد‬ ‫الكهرباء‬ ‫عن‬ ‫وحدة‬ ‫ال‬ ‫لعسل‬ ‫كافة االتصاالت‬ ‫يجب إزالة‬ 경고! 이 장치에는 한 개 이상의 전원 공급 단자가 연결되어 있을 수 있습니다. 이 장치에 전원을...
  • Page 24: Comply With Local And National Electrical Codes

    UPER ERVER "servername" User's Manual ‫מתח בפנל האחורי‬ !‫הרה‬ ‫אז‬ ‫קיימת סכנת מתח בפנל האחורי בזמן תפעול המערכת. יש להיזהר במהלך‬ .‫העבודה‬ ‫اللىحة‬ ‫أوالطاقة المىجىدة على‬ ‫التيار الكهزبائي‬ ‫مه‬ ‫خطز‬ ‫هناك‬ ‫هذا الجهاس‬ ‫خدمة‬ ‫كه حذرا عند‬ ‫يعمل‬ ‫النظام‬ ‫عندما يكىن‬ 경고! 시스템이...
  • Page 25: Product Disposal

    Chapter 4: Warning Statements for AC Systems Attention L'équipement doit être installé conformément aux normes électriques nationales et locales. ‫תיאום חוקי החשמל הארצי‬ !‫אזהרה‬ ‫הציוד חייבת להיות תואמת לחוקי החשמל המקומיים והארציים‬ ‫התקנת‬ ‫المتعلقة‬ ‫المحلية والىطىية‬ ‫قىاويه‬ ‫يجب أن يمتثل لل‬ ‫الكهربائية‬...
  • Page 26: Hot Swap Fan Warning

    UPER ERVER "servername" User's Manual Warnung Die Entsorgung dieses Produkts sollte gemäß allen Bestimmungen und Gesetzen des Landes erfolgen. ¡Advertencia! Al deshacerse por completo de este producto debe seguir todas las leyes y reglamentos nacionales. Attention La mise au rebut ou le recyclage de ce produit sont généralement soumis à des lois et/ou directives de respect de l'environnement.
  • Page 27 Chapter 4: Warning Statements for AC Systems Warnung Die Lüfter drehen sich u. U. noch, wenn die Lüfterbaugruppe aus dem Chassis genommen wird. Halten Sie Finger, Schraubendreher und andere Gegenstände von den Öffnungen des Lüftergehäuses entfernt. ¡Advertencia! Los ventiladores podran dar vuelta cuando usted quite ell montaje del ventilador del chasis.
  • Page 28: Power Cable And Ac Adapter

    Electrical Appliance and Material Safety Law prohibits the use of UL or CSA -certified cables (that have UL/CSA shown on the code) for any other electrical devices than products designated by Supermicro only. 電源コードとACアダプター 製品を設置する場合、 提供または指定された接続ケーブル、 電源コードとACアダプター...
  • Page 29 Appareils électroménagers et de loi sur la sécurité Matériel interdit l'utilisation de UL ou CSA câbles certifiés qui ont UL ou CSA indiqué sur le code pour tous les autres appareils électriques que les produits désignés par Supermicro seulement.
  • Page 30 UPER ERVER "servername" User's Manual Notes 2-20...
  • Page 31: Chapter 3 Chassis Components

    Two 3.5" hard drives with no expansion card. • Four 2.5" hard drives with no expansion card. For the latest parts lists, visit our Web site at: http://www.supermicro.com. *See section 5-3 Installing Hard Drives for illustrations of the options above. Mounting to a Rack (optional) The SC504 can be placed in a rack for secure storage and use.
  • Page 32: Power Supply

    Infrequently, you may need replacement parts for your system. To ensure the highest level of professional service and technical support, we strongly recommend pur- chasing exclusively from our Supermicro Authorized Distributors/System Integrators/ Resellers. A list of Supermicro Authorized Distributors/System Integrators/Resellers can be found at: http://www.supermicro.com. Click the Where to Buy link.
  • Page 33: Chapter 4 System Interface

    Chapter 4: System Interface Chapter 4 System Interface Overview The control panel features an LED display, and the individual drive carriers also feature LEDs. These LEDs keep you constantly informed of the overall status of the system, and monitor the activity and health of specific components. SC504 models feature two buttons on the chassis control panel, an on/off button and a reset but- ton.
  • Page 34: Control Panel Buttons

    SC504 Chassis Manual Control Panel Buttons There are two push-buttons located on the front of the chassis. These are a power on/off button and a reset button. Power: The main power switch is used to apply or remove power from the power supply to the server system.
  • Page 35 Chapter 4: System Interface NIC2: Indicates network activity on GLAN2 when flashing. NIC1: Indicates network activity on GLAN1 when flashing. HDD: Indicates IDE channel activity. SAS/SATA drive and/or DVD-ROM drive activ- ity when flashing. Power: Indicates power is being supplied to the system's power supply units. This LED should normally be illuminated when the system is operating.
  • Page 36 SC504 Chassis Manual Notes...
  • Page 37: Chapter 5 Chassis Setup And Maintenance

    Chapter 5: Chassis Setup and Maintenance Chapter 5 Chassis Setup and Maintenance Overview This chapter covers the steps required to install components and perform mainte- nance on the chassis. The only tool you will need to install components and perform maintenance is a Phillips screwdriver.
  • Page 38: Removing The Chassis Cover

    SC504 Chassis Manual Removing the Chassis Cover Figure 5-1: Removing the Chassis Cover Removing the Chassis Cover 1. Power down the system and disconnect the power cord from the back of the power supply. 2. Remove the five screws that hold the chassis cover in place. There are two screws on each side of the chassis, and one screw on the back.
  • Page 39: Installing The Hard Drives

    Chapter 5: Chassis Setup and Maintenance Installing the Hard Drives Installing 3.5" Hard Drives 3.5" hard drives may be installed in several different configurations. Review the supported configuration options on page 5-5 of this manual. Installing 3.5" Hard Drives 1. Power down the server, disconnect the power cord from the power supply and remove the cover.
  • Page 40 SC504 Chassis Manual Installing 2.5" Hard Drives 2.5" hard drives may be installed in several different configurations. Review the supported configuration options on page 5-5 of this manual. Installing 2.5" Hard Drives 1. Power down the server, disconnect the power cord from the power supply and remove the cover.
  • Page 41: Hard Drive Configuration Options

    Chapter 5: Chassis Setup and Maintenance Hard Drive Configuration Options 2.5" and 3.5" hard drives are supported in the following configurations: Figure 5-2: Two 2.5" HDD's In a Double Bracket, Four HDD's Total, No Expansion Card Figure 5-3 One 3.5" Hard Drive and one Low Profile Expansion Card Figure 5-4: Two 2.5"...
  • Page 42: Installing The Motherboard

    The SC504 chassis supports 9.6" x 9.6" Micro ATX motherboards. Refer to the Supermicro Web site or contact Supermicro for assistance. 2. Power down the server, disconnect the power cord from the power supply and remove the cover.
  • Page 43: Installing The Expansion Card

    For further information on expansionon cards and risers cards, visit the Supermicro web site at www.supermicro.com. One 3.5" or up to two 2.5" drives may be installed with an expansion card. See the supported hard drive configurations in section 5-3 Install- ing Hard Drives, for a list of supported configurations and installation instructions.
  • Page 44 SC504 Chassis Manual 4. Outside of the chassis, put the expansion card and the riser card together by inserting the expansion card into the riser card. 5. Simultaneously insert the PCI slot bracket of the expansion card into the open PCI slot and insert the riser card in to the riser card slot on the motherboard.
  • Page 45: Installing Optional System Fans

    Chapter 5: Chassis Setup and Maintenance Dual Fans Single Fan Figure 5-11: Installing System Fans Installing Optional System Fans Up to three optional system fans may be installed in the SC504 chassis. Installing Optional System Fans 1. Position the dual system fan housing in the front of the chassis, facing for- ward as illustrated above, in front of the motherboard.
  • Page 46: Checking The Chassis Airflow

    This enables it to automatically sense and operate at a 100v to 240v input voltage.In the unlikely event that the power supply module fails, the system will shut down and you will need to replace the power supply module. New units can be ordered directly from Supermicro at http://www.supermicro. com. 5-10...
  • Page 47: Power Supply

    Chapter 5: Chassis Setup and Maintenance Power Supply Replacing the Power Supply Replacing the Power Supply 1. Power down the system, disconnect the power cord and remove the chassis cover. 2. Disconnect all wiring from the power supply. 3. Remove the four screws which hold the power supply in the chassis. Two rear mounting screws are located on the rear of the power supply.
  • Page 48 SC504 Chassis Manual Notes 5-12...
  • Page 49: Chapter 6 Rack Installation

    Chapter 6: Rack Installation Chapter 6 Rack Installation Overview This chapter provides a quick setup to install the chassis into a rack. Unpacking the System You should inspect the box the chassis was shipped in, and note if it was damaged in any way.
  • Page 50: Rack Precautions

    SC504 Chassis Manual Rack Precautions • Ensure that the leveling jacks on the bottom of the rack are fully extended to the floor with the full weight of the rack resting on them. • In single rack installation, stabilizers should be attached to the rack. •...
  • Page 51: Reduced Airflow

    Chapter 6: Rack Installation environment compatible with the manufacturer’s maximum rated ambient tempera- ture (TMRA). Reduced Airflow Equipment should be mounted into a rack so that the amount of airflow required for safe operation is not compromised. Mechanical Loading Equipment should be mounted into a rack so that a hazardous condition does not arise due to uneven mechanical loading.
  • Page 52: Rack Mounting Instructions

    SC504 Chassis Manual Rack Mounting Instructions This section provides information on installing the SC504 chassis into a rack unit There are a variety of rack units on the market, which may mean the assembly procedure will differ slightly. You should also refer to the installation instructions that came with the rack unit you are using.
  • Page 53: Installing The Chassis Into A Telco (Two-Post Style) Rack

    Chapter 6: Rack Installation Mid-Mount Telco Rack The SC504 supports Telco Rack installation. The SC504 chassis compact design allows the chassis to be installed into a Telco rack without the use of rails. Figure 6-2: Installing the Chassis into a Telco Rack Note: figures are for illustrative purposes only.
  • Page 54 SC504 Chassis Manual Notes...
  • Page 55: Appendix A Cables, Screws, And Other Accessories

    This appendix lists supported cables for your chassis system. It only includes the most commonly used components and configurations. For more compatible cables, refer to the manufacturer of the motherboard you are using and our web site at: www.supermicro.com. A-2 Cables Included with SC504 Chassis SC504-200B...
  • Page 56 SC504 Chassis Manual Extending Power Cables Although Supermicro chassis are designed with to be efficient and cost-effective, some compatible motherboards have power connectors located in different areas. To use these motherboards you may have to extend the power cables to the mother boards.
  • Page 57 Appendix A: Chassis Cables A-4 Chassis Screws The accessory box includes all the screws needed to setup your chassis. This section lists and describes the most common screws used. Your chassis may not require all the parts listed. HARD DRIVE Flat head Pan head 6-32 x 5 mm...
  • Page 58 SC504 Chassis Manual Notes...
  • Page 59: Appendix B Power Supply Specifications

    Appendix B: Power Supply Specifications Appendix B Power Supply Specifications This appendix lists power supply specifications for your chassis system. 200W MFR Part # PWS-203-1H 100 - 240V Rated AC Voltage 50 - 60Hz 4-2 Amps +5V standby 2 Amps +12V 16 Amps +5V 8 Amps +3.3V 8 Amps...
  • Page 60 SC504 Chassis Manual Disclaimer (cont.) The products sold by Supermicro are not intended for and will not be used in life sup- port systems, medical equipment, nuclear facilities or systems, aircraft, aircraft devices, aircraft/emergency communication devices or other critical systems whose failure to per- form be reasonably expected to result in significant injury or loss of life or catastrophic property damage.

Table of Contents