CLEARANCES AND HEIGHT REQUIREMENTS

The FP90 may be placed on or near construction
materials. The combustion air kit, fire stop spacer
and roof flashings (not chase flashings) may be
placed directly on or against normal construction
materials. The chimney requires a minimum 2"
(51mm) clearance. A combustible mantle (to
a depth of 10", 254mm) may be installed no
closer than 18" (457mm) above the warm air
vent or 55-1/2" (1410mm) from bottom of unit.
The chimney must be enclosed when installed
in or
passing through a living area where
combustible material or people may come in
contact with it. This is important to prevent
possible personal injury or fire hazard.
For any further information, please call your
dealer. Special restrictions apply to the front
and facing of the fireplace and nearby walls.
No Combustibles on Face of Unit.
Combustibles May Not Extend to
Unit Face.
Do not notch wallboard around
standoffs.
NOTE FOR MANTEL LEGS:
For every 1" (25mm) pretrusion
greater than 5" (127mm), you
must travel away from the unit
1" (25mm) starting at 2" (51mm)
from the edge of the hearth
extension.
WARNING: If insulation is used, do not place
the unit against it. Insulation or vapor barriers,
if used, must be secured to assure insulation
and vapor barriers remain in place and do not
affect the required air spaces.
WARNING: Do not pack or fill required air spaces
with insulation or other material. No material of
any kind is allowed in these areas.
NOTES:
1) Do not insulate the chase cavity with blown
or fill type insulation materials.
2) Local codes may not require firestopping
at the ceiling level
installations; however, it is recommended
for safety and the reduction of heat loss.
3) We recommend that you insulate at least
the first floor of the chase to prevent heat
loss.
4) Some local codes require 1 hour fire rating
on one or all sides of fire chases. Check
with your local authorities.
2"
(51mm)
20" (508mm)
Mantel leg can
go in this
5"
area
(127mm)
Clearances to Combustibles
for outside chase
center line
18" (457mm)
40" (1016mm)
installation
Max. 10" (254mm)
Depth of Mantel
55-1/2" (1410mm)
from bottom of unit
18" (457mm)
FP90 Wood Fireplace |
|