MINIMUM CLEARANCE TO COMBUSTIBLE MATERIALS Please read the section below carefully as clearances depend on whether single wall or double wall pipe is installed on the stove. Measurements "From Unit" are from the top plate of the stove to a side wall or to a corner, and from the rear heat shield to a back wall. Clearances may only be reduced by means approved by the regulatory authority.
MINIMUM ALCOVE CLEARANCE AND CLEARANCE TO COMBUSTIBLE MATERIALS The Regency Freestanding models have been alcove approved and must be installed with a listed double wall connector to the ceiling level. Single wall pipe (C Vent) is not approved for alcoves.
Page 4
FLOOR PROTECTION (CORNER INSTALLATION) A combustible floor must be protected by non-combustible material (like tile, concrete board, or certified to UL-1618 or as defined by local codes) extending beneath the heater and a minimum of 8" (203mm) from each side and minimum 16" (406mm)** from the front face of the stove and minimum 6"...
MOBILE HOME INSTALLATION In addition to standard installation instructions the following requirements are mandatory for For Canadian Installations: see Outside installation in a mobile home. Air Kit - Part # 846-502. There are further requirements when installing 1. The stove must be permanently bolted to this unit into a mobile home in Canada Only.
Page 6
F1500 MOBILE HOME KIT - FOR CANADA Mobile Home Kit - For Canada Note: The optional ashdrawer cannot be used when using the Mobile Home Kit. Note: The optional ash drawer cannot be used when using the Mobile Home Kit. The Mobile Home kit contains: 5.
Page 7
STEP-BY-STEP This stove may be connected to a lined masonry 9. NOTE: Residential Close Clearance chimney or a listed factory built chimney suitable and Alcove installations require a CHIMNEY AND for use with solid fuels and conforming to ULC629 listed double wall connector from CONNECTOR INSTALLATION the stove collar to the ceiling level.
MASONRY CHIMNEY Ensure that a masonry chimney meets the minimum standards of the National Fire Protection Association (NFPA) by having it inspected by a professional. Make sure there are no cracks, loose mortar or other signs of deterioration and blockage. Have the chimney cleaned before the stove is installed and operated.
COMBUSTIBLE WALL CHIMNEY CONNECTOR PASS-THROUGHS Method A: 12" (304.8 mm) Clearance to Combustible Wall Member: Minimum chimney clearance to brick and combustibles 2 in. (50.8mm) Using a minimum thickness 3.5" (89 mm) brick and a 5/8" (15.9 mm) minimum wall thickness clay liner, construct a wall pass-through. The Minimum clearance clay liner must conform to ASTM C315 (Standard Specification for 12 in.
TABLE 1 MINIMUM RECOMMENDED FLUE HEIGHTS IN FEET (Measured from the top of the unit) # OF ELBOWS ELEVATION (FT) ABOVE SEA LEVEL 2 x 15 4 x 15 2 x 30 4 x 30 2 x 45 4 x 45 0-1000 12.0 13.0...