Regency F2402M Owner's And Installation Manual

Freestanding woodfire

Advertisement

Owners &
Installation
Freestanding Woodfire
Vancouver
PLEASE KEEP THESE INSTRUCTIONS FOR
FUTURE REFERENCE
WARNING:
Improper installation, adjustment, altera-
tion, service or maintenance can cause
injury or property damage. Refer to this
manual. For assistance or additional in-
formation consult an authorised installer,
service agency or the gas supplier.
FOR YOUR SAFETY
Do not store or use gasoline or other flam-
mable vapours and liquids in the vicinity of
this or any other appliance.
Installation and service must be performed
by an authorised installer, service agency or
the gas supplier.
FPI - FIREPLACE PRODUCTS AUSTRALIA PTY LTD.
918-348c
1-3 CONQUEST WAY HALLAM VICTORIA 3803
Model: F2402M
FOR YOUR SAFETY
What to do if you smell gas:
Do not try to light any appli-
ance
Do not touch any electri-
cal switch: do not use any
phone in your building.
Immediately call your gas
supplier from a neighbour's
phone. Follow the gas sup-
plier's instructions.
If you cannot reach your
gas supplier, call the fire
department.
12/20/16

Advertisement

Table of Contents
loading

Summary of Contents for Regency F2402M

  • Page 1 Owners & Installation Freestanding Woodfire Vancouver Model: F2402M PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE WARNING: FOR YOUR SAFETY Improper installation, adjustment, altera- What to do if you smell gas: tion, service or maintenance can cause Do not try to light any appli- injury or property damage.
  • Page 2 The pride of workmanship that goes into each of our products will give you years of trouble-free enjoyment. Should you have any questions about your product that are not covered in this manual, please contact the REGENCY DEALER in your area.
  • Page 3 Modular Parts F2400/S2400 Freestanding Woodfire...
  • Page 4: Table Of Contents

    table of contents Optional Accessories Installation SAFETY LABEL - Pedestal Ash Drawer Kit ..........17 - Bottom Shield Ashdrawer Kit........17 Copy of Data Badge ..............4 - Screen Door ...............17 - Blower/Fan ..............18 INSTALLATION - Blower/Fan Wiring Diagram ........18 Unit Dimensions ..............5 OPERATING INSTRUCTIONS Residential Installation ............6 Modular Installation Options ..........6...
  • Page 5: Copy Of Data Badge

    This is a copy of the label that accompanies each NOTE: Regency units are constantly being Regency Freestanding Wood heater (F2402M). improved. Check the label on the unit and if We have printed a copy of the contents here there is a difference, the label on the unit is the correct one.
  • Page 6: Unit Dimensions

    DIMENSIONS dimensions 27-3/8 (695mm) 24-7/8 (632mm) 6-5/8 (168mm) 24 (610mm) F2400/S2400 Freestanding Woodfire...
  • Page 7: Installation

    WARNING: ONLY USE SPECIFIED COMPONENTS. The following items are required when assembling your Regency Stove. F2402 unit - the Rear Heat Deflector is supplied with the stove, but if you choose not to use it you must use the Airmate instead.
  • Page 8: Minimum Clearance To Combustibles

    AUSTRALIA ONLY IMPORTANT The Regency F2402M has been tested with the flue kits listed Use only the instructions and clearance dimensions on this page for below. A default flue kit as listed in AS/NZS 2918:2001 may also heaters to be installed in Australia.
  • Page 9: Minimum Alcove Clearances

    Minimum Alcove Clearance to Combustible Materials The Regency Freestanding models have been alcove approved and must be installed with a listed double wall connector to the ceiling level. Note: Minimum alcove ceiling height - 84" (2134mm) Maximum depth of alcove - 36" (914mm)
  • Page 10: Heater Assembly Prior To Installation

    All units require either the pedestal or 4 legs at- The rear heat deflector is supplied with the stove tached to the base. The F2402M stove requires and must be installed unless the optional airmate either the Airmate or Rear Heat Deflector on top has been selected.
  • Page 11: Flue Baffle And Secondary Air Tube Installation

    installation FLUE BAFFLE & SECONDARY AIR TUBE INSTALLATION The flue baffle system located in the upper area of the firebox is removable to make cleaning your flue system easier. The baffles must be installed prior to your first fire. Smoke spillage and draft problems may occur if the baffles are improperly positioned. Check the position of the baffles on a regular basis as they can be dislodged if too much fuel is forced into the firebox.
  • Page 12: Leg And Bottom Shield Assembly

    Ensure that the legs 5) Place the storm collar over the flashing, are properly aligned with heat shield and 4) Push the Regency logo into the two holes in sealing the joints with a silicone caulking. tighten the bolts.
  • Page 13: Masonry Flue

    installation 6) Fasten the raincap with spark screens (if In addition to standard installation instructions required) to the top of your flue. the following requirements are mandatory for installation in a mobile home. 7) For optimum efficiency when installing into a masonry flue, size accordingly, i.e.
  • Page 14: Masonry Fireplace

    installation MASONRY FLUE Ensure that a masonry flue meets the minimum standards of the National Fire Protection As- sociation (NFPA) by having it inspected by a professional. Make sure there are no cracks, loose mortar or other signs of deterioration and blockage.
  • Page 15: Combustible Wall Flue

    installation COMBUSTIBLE WALL FLUE CONNECTOR PASS-THROUGHS Minimum chimney clearance to brick and combustibles 2 in. (50.8mm) Method A: 12" (304.8 mm) Clearance to Combustible Wall Member: Minimum clearance Using a minimum thickness 3.5" (89 mm) brick and a 5/8" (15.9 12 in.
  • Page 16: Recommended Height For Wood Heater Flue

    installation RECOMMENDED HEIGHTS FOR WOOD HEATER FLUE Simple rules on draft. See Table 1. 1) At sea level minimum height is 12' (3.7m) Example: a) Recommended Flue Height 1-1/2 ft. of horizontal run = 3 ft. (.9m) straight. one "T" = 3 ft.
  • Page 17: Mobile Home Installation

    INSTALLATION Front View ICC EXCEL 2100 Qty.Part # Description The Regency F2402M and S2402M Freestand- 6CL48 48" (1219mm)Flue length ing pedestal units are approved for installation (also in 12" (305mm), 18" in a Mobile Home if one of the following pipe (457mm), 24"...
  • Page 18: Brick Installation

    installation BRICK INSTALLATION STEP-BY-STEP 4) Push the ash plug into the hole inside the firebox and replace all the bricks except OPTIONAL for the brick over the ash plug. See brick Firebrick is included to extend the life of your ACCESSORIES diagram.
  • Page 19: Blower/Fan

    installation 1) Remove the two screws from the top of the #8 Groun Lug Grounding fan housing. Lug Detail Ground wire from fan Lockwasher 2) Slide the fan up into the rear heat shield. Star washer 3) After aligning holes, secure the fan to the rear Star washer heat shield using the two screws removed Ground wire...
  • Page 20: Operating Instructions

    4) After about 45 minutes, when your wood created by your Regency Heater causing a Both the primary and air wash drafts are control- draft down your flue. If this occurs, slightly...
  • Page 21: Fan Operation

    When the drawer is completely out, slide the cover plate over the ash drawer Manual 7) Your Regency heater can be very hot. You and carry away. To manually operate the fan system push the may be seriously burned if you touch the bottom switch to "MAN"...
  • Page 22: Maintenance

    The creosote vapours condense in the relatively cool flue of a DOOR GASKET Your Regency heater is supplied with 5 mm slow burning fire. As a result, creosote residue Neoceram ceramic glass (Part #846-302) that accumulates on the flue lining. When ignited, If the door gasket requires replacement 7/8"...
  • Page 23: Parts List

    Fan Speed Switch HI/OFF/LOW (3-way) 820-184 Glass Retainer Clips (8/set) 910-155/P Fan/Blower Motor (240 V) Screw - 1/4 - 20 x 3/8" 033-953 Air Tube - 3/4" F2402M (Qty: 4) 948-170/P Small Glass Retainer F2402M 020-957 Baffle (set) F2402M 846-973 Door Handle Assembly...
  • Page 24: Pedestal, Bottom Shield And Legs

    Ash Plug Tool Handle 140) 850-126 Legs - Cast Black 850-127 Legs - Cast Gold 850-128 Legs - Cast Brush Nickel 142) 850-125 Legs - Steel Black 948-216 Logo - Regency *Not available as a replacement part. F2400/S2400 Freestanding Woodfire...
  • Page 25: Firebrick

    parts list PARTS LIST FIREBRICK Part # Description 020-960 Brick Set Complete Brick - Regular Full Size: 1-1/4" x 4-1/2" x 9" Brick Partial: 1-1/4" x 4-1/2" x 3-1/2" Brick Partial: 1-1/4" x 4-1/2" x 2" Brick Partial: 1-1/4" x 2" x 9" F2400/S2400 Freestanding Woodfire...
  • Page 26: Warranty

    FPI Fireplace Products International Ltd. (“the manufacturer”) through its wholly owned subsidiary, Fireplace Products Australia Pty Ltd (for Australia and New Zealand customers) and sold under the Regency® brand of fireplace products (collectively referred to herein as “FPI”), extends this Limited Warranty to the original purchaser of this appliance provided the product remains in the original place of installation.
  • Page 27: Warranty

    Unit must be installed according to all manufacturers’ instructions as per the manual. All Local and National required codes must be met. The installer is responsible to ensure the unit is operating as designed at the time of installation. Revision Date: December 2016 Regency Wood Products Warranty F2400/S2400 Freestanding Woodfire...
  • Page 28 Products made or provided by other manufacturers and used in conjunction with the FPI appliance without prior authorisation from FPI may void this warranty. INCORRECT INSTALLATION IS NOT COVERED BY WARRANTY. A SERVICE OR CALLOUT FEE WILL BE CHARGED IN THESE CIRCUMSTANCES. Revision Date: November 2016 Regency Wood Products Warranty F2400/S2400 Freestanding Woodfire...
  • Page 29 (including negligence), statute or otherwise. (b) Loss means any expense, cost or damage of any kind and includes Consequential Loss and a fine or penalty imposed by a statutory or other authority. Revision Date: December 2016 Regency Wood Products Warranty F2400/S2400 Freestanding Woodfire...
  • Page 30 Product Registration and Customer Support: Thank you for choosing a Regency Fireplace. Regency strives to be a world leader in the design, manufacture, and marketing of hearth products. To provide the best support for your product, we request that you complete a product registration form at http://www.regency-fire.com.au/Customer-Care/Warranty-Registration.aspx...
  • Page 31 Product Registration and Customer Support: Thank you for choosing a Regency Fireplace. Regency strives to be a world leader in the design, manufacture, and marketing of hearth products. To provide the best support for your product, we request that you complete a product registration form found on our Web Site under Customer Care within ninety (90) days of purchase.
  • Page 32 F2400/S2400 Freestanding Woodfire...
  • Page 33 NOTES notes F2400/S2400 Freestanding Woodfire...
  • Page 34 notes NOTES F2400/S2400 Freestanding Woodfire...
  • Page 35 F2400/S2400 Freestanding Woodfire...
  • Page 36 Installer: Please complete the following information Dealer Name & Address: ______________________________________________ ___________________________________________________________________ Installer: ___________________________________________________________ Phone #: ___________________________________________________________ Date Installed: ______________________________________________________ Serial No.: __________________________________________________________ © Copyright 2017, FPI Fireplace Products International Ltd. All rights reserved.

This manual is also suitable for:

Vancouver

Table of Contents