Table of Contents

Advertisement

Quick Links

Owners &
FP90 Wood Fireplace
Installation Manual
Canadian Edition
Regency High Efficiency EPA Certified Fireplace
MODEL: FP90
www.regency-fire.com
Tested by:
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
918-426j
02.04.15

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FPI FP90 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Regency FPI FP90

  • Page 1 Owners & FP90 Wood Fireplace Installation Manual Canadian Edition Regency High Efficiency EPA Certified Fireplace MODEL: FP90 www.regency-fire.com Tested by: Installer: Please complete the details on the back cover and leave this manual with the homeowner. Homeowner: Please keep these instructions for future reference.
  • Page 2 States. This means that it meets the strictest standards in providing you with the latest in clean burning technology and efficiency. Specifications may vary widely. Consult with your fpi dealer for local considerations. Keep those reGencY fires burning. http://oee.nrcan.gc.ca/residential/personal/retrofit-homes/retrofit-qualify-grant.cfm FPI FP90 Wood Fireplace...
  • Page 3 FPI FP90 Wood Fireplace...
  • Page 4: Table Of Contents

    INSTALLATION COMPONENTS DIAGRAM ..12 Installation Components ........12 HeatWaVe Kit (not epa approVed) Installing The Stand-offs ..........14 Set The Regency FP90 Into Position ......14 Listings And Code Approvals ........32 Installing The Chimney System ........14 General Information .............32 Offset Chimney Installation ........15 Important Installation Notes .........32...
  • Page 5: Safety Label

    This is a copy of the label that accompanies each Regency Fireplace. note: Regency units are constantly being improved. Check the label It is located inside the lower louver opening on the left side. We have on the unit and if there is a difference, the label on the unit is the correct printed a copy of the contents here for your review.
  • Page 6: Product Details

    Surround Accent Gold Excalibur EX90 Surround Accent Brush Nickel Excalibur EX90 Wood Screen R90/EX90 Finishing Trim R90 Masonry Retainer Kit R90 Gravity Vent Kit R90 8" (203mm) - 7" (178mm) Adaptor R90/EX90 1" Unit Base Standoffs Heatwave Kit FPI FP90 Wood Fireplace...
  • Page 7: Read Before You Install

    16) do not use a fireplace insert or any other components and accessories, may void the product not specified by Regency for use warranty, listing and approvals of this system 9) Ashes should be placed in a metal with this fireplace.
  • Page 8: Dimensions And Specifications

    The Regency is a wood burning fireplace featuring This fireplace system is designed for installation The FP90 main unit consists of the following: a self-contained heat-circulating system and cast- in accordance with the National Fire Protection iron doors with large viewing windows.
  • Page 9: Clearances And Height Requirements

    Max. 10" (254mm) Depth of Mantel center line 18" (457mm) 55-1/2" (1410mm) from bottom of unit 20" (508mm) 18" (457mm) 40" (1016mm) Clearances to Combustibles FPI FP90 Wood Fireplace...
  • Page 10: Installation Of Nailing Strips

    Nailing Strips. The Nailing Strips can Building structures cannot encroach on also be moved forward and back by adjusting chase the screws that mount them to the fireplace. FPI FP90 Wood Fireplace...
  • Page 11: Framing Details

    Note: The “Z” type safety strip is not supplied by regency and must be fabricated locally. 2 x 6 Stud FINISHING MATERIAL Wall with a FireStop 2 x 4 Header Fire Stop Straightrun 10" (254mm) for 8"(203mm)
  • Page 12: Before You Start

    A chase is a vertical box-like structure constructed to surround the fireplace and chimney. A ventilated chase cap is highly Regency’s FP90 Fireplace is to be installed recommended. Refer to flue manufacturer's with one of the following Chimney Systems instructions for reduced flue heights above chase only.
  • Page 13: Installation Measurements / Framing Details

    6) MUST MAINTAIN A MIN. OF 24" (610mm) TO SIDE WALL FROM THE EDGE OF THE TOP LOUVER OPENING. 7) HEARTH MUST BE A MIN. OF 40" (1016mm) WIDE x 18" (457mm) deep and 1/2" (127MM) THICK. FPI FP90 Wood Fireplace...
  • Page 14: Installing The Stand-Offs

    Please refer to Table 2 will strip the gold plate. firebricks for Flue Heights (page 15). are fragile and should be handled with caution. FPI FP90 Wood Fireplace...
  • Page 15: Offset Chimney Installation

    Check for hot embers around the unit and outside your home; extinguish. Do not use your fireplace again until it has been inspected by a qualified person. FPI FP90 Wood Fireplace...
  • Page 16: Installing The Outside Air Kit

    Insulated Metal Vent 6” Duct 2) Ensure that your air source is not close to automobile exhaust, gas meters or other Outside Air Inlet must be 6 ft. (152mm) below vents. the chimney termination point FPI FP90 Wood Fireplace...
  • Page 17: Wiring The Fp90

    Power Chord 910-619 Neutral - from Fan separations. Through the use of two separate Ground blower systems, Regency has developed 919-885 the basic blower wiring options listed in the diagrams shown. Thermodisc 910-142 P60T12...
  • Page 18: Finishing The Regency Fp90

    If you are installing a thin veneer facade the (vent cover 'B') and slide it back under the 9) Pull the insulation sleeve up the flex vent Regency Masonry Retainer Kit is recommended. insulation. to the back of the mounting frame. The flex...
  • Page 19: Masonry Retainer Kit Option

    Depending on the installation, heavier LEFT RIGHT reinforcing wire screen may be required to SIDE SIDE bridge the stand-off spacer area around the perimeter of the unit. Hold in position with 2 screws while the door arch is centered. FPI FP90 Wood Fireplace...
  • Page 20: Finishing Details

    Header. example 1: face of fireplace flush with Wall framing. Stone, Tile or Brick Mortar Heavy Expanded Metal Non-Combustible Top View Material example 2: face of fireplace flush with non-combustible. Top View FPI FP90 Wood Fireplace...
  • Page 21: Masonry Liner / Bricks

    The air tube will be difficult to snap into place because it has Side to be a snug fit in order to prevent it from Panel falling out when a fire is burning. Top Panel Insulation Brick Bottom Fermiculite FPI FP90 Wood Fireplace...
  • Page 22: Ash Drawer Kit Option

    6) Slide the ash drawer into the ash drawer shelf. 7) Place the lid and the ash plug tool on the fan trasfer plate for storage. FPI FP90 Wood Fireplace...
  • Page 23: Fan Installation

    Ensure that no wires will come in contact with any hot surfaces. See Diagram 3. 9) Reinstall the thumb screw. Diagram 3 GREEN GROUND THERMODISC GREY GREY BROWN BLUE GROUND GREEN SWITCH CONTROL BOX Diagram 2 POWER CORD 918-437 11.10.14 FPI FP90 Wood Fireplace...
  • Page 24: Masonry Cover Plate Installation

    SO THAT THE 3/4" (19mm) FLANGES ARE ON THE INSIDE OF THE OPENING. SLOTTED HOLES ON RIGHT SIDE ONLY 43.000" (1092mm) NOTE: ONCE THE TEMPLATE IS MOUNTED CHECK TO MAKE SURE THE SIDES ARE PLUMB AND 43" (1092mm) IN WIDTH FPI FP90 Wood Fireplace...
  • Page 25 TO PREVENT MASONRY FACING MATERIAL FROM HITTING THE TOP STIFFENER LOCATED ON THE BACK OF THE SURROUND WHICH IS HIGHER THAN THIS EDGE. INSTALL THE SURROUND TEMPLATE ONTO THE UNIT WITH THE SAME MOUNTING SCREWS AS THE SURROUND. FPI FP90 Wood Fireplace...
  • Page 26: Finishing Trim Kit Installation

    fl ush with the face of the unit and allow the trim to be installed correctly (refer to Diagram 1). Front Trim Side Side Trim Trim Unit With Finished Trim Diagram Assembly De tails 918-442a PAGE 1 OF 2 10/10/06 FPI FP90 Wood Fireplace...
  • Page 27 8) It is recommended that the joints of the sheathing run horizontal from the top corners of the unit rather than vertical. This will reduce the heat exposure to the joints and reduce the chance of the fi nish from cracking. 918-442a PAGE 2 OF 2 10/10/06 FPI FP90 Wood Fireplace...
  • Page 28: Fireplace Screen Installation

    fi rebox fl anges. 2) Fasten the handles to the screen using the fasteners provided. Front View Side View 3) Install fi rescreen. Side View FPI FP90 Wood Fireplace 918-444 01/12/06...
  • Page 29: Regency Louver Installation

    NOTE: Take care not to scratch the paint on the front of the fi replace when installing the top louver. Bottom Louver Frame Rotation Pin Tab (x2) Top Louver Mounting Tab (x2) Bottom Louver Rotation Pin Tab (x2) Diagram 2 Diagram 1 Bottom Louver Mounting Sequence 918-433 08/23/05 FPI FP90 Wood Fireplace...
  • Page 30: Excalibur Faceplate Installation

    Optional: 4) Install the optional masonry cover plate to the facing guides with four (4) screws (¼-20 x ½”). 43” (1092mm) 918-434 11/12/09 FPI FP90 Wood Fireplace...
  • Page 31: Excalibur Accent Kit Installation

    Place the emblem over the emblem design on the sur- round. Insert the studs through the holes. To secure them fi rst put on the split lock washer and then the nut and tighten. 918-438 08/23/05 FPI FP90 Wood Fireplace...
  • Page 32: Heatwave Kit (Not Epa Approved)

    Diagram 1: Guide for possible air duct runs and locations. Keep duct length and number of bends to a miniumum. Maximum duct length is 20 ft. (6.1m) per kit. FPI FP90 Wood Fireplace...
  • Page 33: Minimum Framing Clearances

    Attach the 6" round air duct (supplied) to the fireplace collar and run the duct to the fan housing. Attach the round-to-oval adaptor to the fan housing and the air duct to the adaptor. FPI FP90 Wood Fireplace...
  • Page 34: Wiring Diagram

    Heat Wave air duct kit fan is operating. FPI FP90 Wood Fireplace...
  • Page 35: Operating Instructions

    If creosote your draft control down to keep the fire at a away from the unit while in use. has accumulated it shall be removed to moderate level. reduce the risk of a chimney fire. FPI FP90 Wood Fireplace...
  • Page 36: Maintenance

    34" (864mm) long for each side. brush. A proper high temperature gasket adhesive is Allow the stove to cool before removing or required. Contact your dealer for the Regency replacing glass. Remove the door from the e. Replace chimney cap. Gasket Repair Kit.
  • Page 37: Parts List

    Ash Drawer Lid Border Frame - Bottom Grille 942-110 Ash Plug Louver Support Frame - Bottom Grille 820-375 Ash Hole Cover Plate Retainer Plate 9) 948-326 Intake Pipe 6" 948-327 Intake Pipe Insulation 948-416 6" Outside Air Kit FPI FP90 Wood Fireplace...
  • Page 38: Parts List- Baffles, Door, Options

    Rope Gasket 5/8 Med Desnity 001-551 Door Handle Assembly Complete - Right 936-243 Tape 7/8 Window Adhesive 001-137 Steel Handle - Left Door 936-299 Tape 3/16 X 3/8in. 001-138 Steel Handle - Right Door 001-147F Anchor Bracket - Left Handle FPI FP90 Wood Fireplace...
  • Page 39: Warranty

    The authorized selling dealer is responsible for all in-fi eld service work carried out on your Regency product. FPI will not be liable for results or costs of workmanship from unauthorized service persons or dealers.
  • Page 40 & address: ______________________________________________ ___________________________________________________________________ installer: ___________________________________________________________ phone #: ___________________________________________________________ date installed: ______________________________________________________ serial no.: __________________________________________________________ Regency is a trademark of FPI Fireplace Products International Ltd. printed in canada © Copyright 2012, FPI Fireplace Products International Ltd. All rights reserved.