Air Diverter Installation Instructions - L.B. White AD100 Owner's Manual

Agricultural animal confinement building brood heater
Table of Contents

Advertisement

-- If necessary, replace the parts or components
involved if the leak cannot be stopped.
-- Ensure all gas leaks have been identified and
repaired before proceeding.
12. A qualified service agency must check for proper
operating gas pressure upon installation of the brood
heater.
13. Light according to instructions on the brood heater or
within owner's manual.
14. It is extremely important to use the proper size and
type of gas supply line to assure proper functioning of
the brood heater. Contact your fuel gas supplier for
proper line sizing and installation.
15. This brood heater can be configured for use with
propane gas, propane/butane gas mix, or natural gas.
Consult the dataplate, located on interior of the burner
end or motor end door, for the gas configuration of the
specific brood heater. Do not use the brood heater in
a propane liquid withdrawal system or application. If
you are in doubt, contact the L.B. White Co., Inc.
16. Eventually, like all electrical/mechanical devices, the
thermostat can fail. Thermostat failure may result in
either an underheating or overheating condition which
may damage critical products and/or cause animal
AIR DIVERTER
INSTALLATION INSTRUCTIONS
Accessory- must be ordered separately
(Appearance of the outlet on brood heater may vary from model to model.)
1. Air diverters can be installed in the brood heater
outlet to provide direction to the heated air as it exits
the brood heater. Installation options include
installing the diverters in such a way as to broadly
distribute the air in two 45 degree paths or to focus
the air flow in one 45 degree direction. See Fig. 1.
2. The air diverters may require hand forming prior to
installation. Make 90 degree bends utilizing the
performations provided. The diverter should then
have the shape shown in Fig. 1.
3. The air diverter's tabs on each half will pop into the
blower outlet between the inside of the case
assembly and the blower housing outlet. If the
notched tabs do not pop into the blower outlet,
loosen (do not remove) the blower outlet screws.
Doing this provides a gap into which you can insert
the tabs. Retighten the screws after installation.
8
injury or death. Critical products and/or animals
should be protected by a separate back-up control
system that limits high and low temperatures and also
activates appropriate alarms.
17. Take time to understand how to operate and maintain
the brood heater by using this Owner's Manual. Make
sure you know how to shut off the gas supply to the
building and also to the individual brood heater.
Contact your fuel gas supplier if you have any
questions.
18. Any defects found in performing any of the service or
maintenance procedures must be eliminated and
defective parts replaced immediately. The brood
heater must be retested by properly qualified service
personnel before placing the brood heater back into
use.
19. Do not exceed input rating stamped on the dataplate
of the brood heater. Do not exceed the burner
manifold pressure stated on the dataplate. Do not
use an orifice size different than specified for the
specific input rating of this brood heater, fuel type
configuration and altitude.
FIG. 1
(Typical installation allowing two directions of air movement.)
TABS
DIVERTER
HALVES
Alternate Air Diverter Installations
NOTCHES IN MOUNTING TABS
OUTLET
SCREWS
FORMED
OUTLET GUARD

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Ad250Ad060Ad325

Table of Contents