Air Proving Switch

Safety device used to insure that the proper air flow is being
achieved before the gas valve is opened.
Burner
Cast iron component used to channel gas and provide an
area at which the fuel may ignite.
Burner Orifice
Brass metering device used to feed gas to burner at a
specific rate.
Fan Housing
Chamber used for compressing air for ef ficient air
movement.
Fan Wheel
Component used in conjunction with the motor and fan
housing to pull the hot air from heater and blow it into room
for heating (also known as a "squirrel cage").
Gas Control Valve
A device which consists of a low pressure regulator and
electrical solenoids which are used for the control of gas
flow to the burner assembly. A feature of the control is a
built in gas shut off which is used to isolate the brood heater
from its gas supply when servicing.
Gas Hose
Flexible connector used to convey gas from supply line in
building to brood heater.
Heat Chamber
Metal "fire box" within the appliance that provides an area
where burner flame mixes with combustion air thereby
providing heat.

High Limit Switch

Safety device wired into the control system which is used to
break an electrical circuit to the gas control valve in event of
overheat situation.

Brood Heater Component Function

Ignition Control Module
Controls the ignition sequence and operation of the brood
heater as well as monitoring the safety sevices. A major
service feature is the board's ability to diagnose component
and flame failure by means of a diagnostic light located
within the module. This light will provide a specific flash
pattern repetitively, depending on the type of componenet
failure that has occurred.

Igniter/Flame Sensor Assembly

This assembly consists of two components mounted
adjacent on the same bracket.
-- Spark Igniter: Electrical ignition device used on
automatic ignition control systems. Ignites gas by a
spark.
-- Flame Sensor: Also known as a flame rod or flame
probe, this device works in conjunction with the ignition
module in proving that burner flame has been
established.
Motor
Electric device used to force preheated air through the
brood heater and to circulate heat within a certain area.
Converts electrical energy into mechanical energy.
Regulator
The heart of any gas supply installation. Used to deliver a
working pressure to the appliance under varying conditions
in tank pressure.
Thermostat
Electrical device used as an automatic "on/off" switch
which will respond to changes in temperature in a certain
area.
Throttle Valve
Manually adjustable component used to increase or
decrease the flow of gas to the burner. The throttle valve is
located between the gas control valve and burner assembly.
Transformer
This device is responsible for reducing a higher incoming
voltage (220 V.A.C.) to a lower outgoing voltage. The lower
voltage (24 V.A.C.) is essential to operate the ignition control
module.