L.B. White AD100 Owner's Manual page 15

Agricultural animal confinement building brood heater
Table of Contents

Advertisement

Refer to Fig. 11 (AD100/250) or Fig. 12 (AD060) for
servicing of the igniter assembly.
The igniter/sensor assembly may require cleaning due
to accumulations of dust and dirt over a period of
time, affecting its ability to ignite fuel gas and sense
burner flame. Cleaning will require igniter/sensor
removal.
-- If spark appears to be weak, rub the igniter
electrode with emery cloth or steel wool to remove
any buildup.
FIG. 11
TO REMOVE IGNITER / SENSOR WITH ENCLOSURE
REMOVE SCREW AND SLIDE THE ENCLOSURE'S
MOUNTING TABS FROM SLOTS IN HEAT CHAMBER.
FIG. 12
17,6 kW: 3 mm
3 mm
65,9 kW: 4 mm
BURNER
BURNER
LOOSEN SCREW AND SLIDE
TO GAP IGNITER LOOSEN SCREW.
MOVE ENCLOSURE UP OR DOWN
ASSEMBLY UP/DOWN TO MAINTAIN
TO ALLOW PROPER POSITIONING
PROPER GAP.
OF IGNITER TO BURNER.
REMOVE SCREW, LIFT ASSEMBLY
FROM ITS MOUNTING SLOTS
IGNITER ENCLOSURE
IGNITER / SENSOR
ENCLOSURE
FLAME SENSOR
IGNITER
IGNITER
IGNITER AND FLAME SENSOR ASSEMBLY
--- If the spark appears strong but the brood heater
cycles off, rub the sensor rod with emery cloth or
steel wool to remove any build-up.
Ensure the igniter gap to burner is 3 mm and the
igniter tip is positioned over the burner port according
to the illustration below.
SENSOR
SENSOR
SENSOR LEAD
FLAME SENSOR
REMOVE SCREW (65,9 kW MODEL ONLY)
BURNER
BURNER
IGNITER
IGNITER
2.5 mm - 4.5 mm
mm GAP to BURNER
3
HEAT CHAMBER
HEAT CHAMBER FACE
BURNER
BURNER
IGNITER LEAD
HEAT CHAMBER
HEAT CHAMBER
IGNITER / SENSOR
IGNITER/SENSOR
ENCLOSURE
ENCLOSURE
LOOSEN SCREWS AND SLIDE IGNITER
REMOVE SCREWS
UP/DOWN TO MAINTAIN PROPER GAP.
REMOVE SCREWS AS NEEDED FOR
SERVICING IGNITER ASSEMBLY
15

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Ad250Ad060Ad325