Mitsubishi Electric plfy-p vcm-e3 Installation Manual page 10

Air conditioner for building application (indoor unit)

Advertisement

 ,QVWDOOLQJ WKH JULOOH
)LJ 
)LJ 
)LJ 
6/3$/:
)LJ 

A
Button
B
Vane motor
C
8SGRZQ YDQHV
D
Connector
E
Measurement standard
position of grille
F
8SGRZQ YDQHV
 :LUH FRQQHFWLRQ )LJ 
‡ %H VXUH WR FRQQHFW WKH XQLW WR WKH FRQQHFWRU ZKLWH SROHUHG SROH  1H[W DW-
tach the white glass tube that comes with the main unit so that the tube covers the
connector. Close the opening of the glass tube with the band.
‡ 0DNH VXUH WKDW WKHUH LV QR VODFN LQ WKH HDFK OHDG ZLUH DW WKH IDVWHQHU RQ WKH JULOOH
A
Fastener (Accessory)
B
White glass tube
C
Connector of the main unit
D
Connector of the grille
E
Band (Accessory)
F
Receiver (for SLP-2ALW)
 /RFNLQJ WKH XSGRZQ DLUIORZ GLUHFWLRQ )LJ 
The vanes of the unit can be set and locked in up or down orientations depending
upon the environment of use.
‡ 6HW DFFRUGLQJ WR WKH SUHIHUHQFH RI WKH FXVWRPHU
7KH RSHUDWLRQ RI WKH IL[HG XSGRZQ YDQHV DQG DOO DXWRPDWLF FRQWUROV FDQQRW EH
performed using the remote controller. In addition, the actual position of the vanes
may differ from the position indicated on the remote controller.
1
Turn off the main power switch.
Injuries and or an electrical shock may occur while the fan of the unit is rotating.
2
Disconnect the connector for the vane motor of the vent that you want to lock.
(While pressing the button, remove the connector in the direction indicated by
the arrow as shown in the diagram.) After removing the connector, insulate it with
tape.
3
7R DGMXVW WKH GHVLUHG DLUIORZ GLUHFWLRQ VORZO\ PRYH WKH XSGRZQ YDQHV ZLWKLQ WKH
VSHFLILHG UDQJH )LJ
6SHFLILHG UDQJH
8SGRZQ DLUIORZ
+RUL]RQWDO ƒ
'RZQZDUG ƒ
direction
A (mm)
21
‡ 7KH YDQHV FDQ EH VHW EHWZHHQ  DQG  PP
&DXWLRQ
'R QRW VHW WKH XSGRZQ YDQHV SDVVHG WKH VSHFLILHG UDQJH &RQGHQVDWLRQ FRXOG
IRUP RQ DQG GURS IURP WKH FHLOLQJ RU WKH XQLW FRXOG PDOIXQFWLRQ
 ,QVWDOOLQJ WKH LQWDNH JULOOH )LJ 
‡ 3HUIRUP WKH SURFHGXUH WKDW LV GHVFULEHG LQ ³ 3UHSDULQJ WR DWWDFK WKH JULOOH´ LQ
reverse order to install the intake grille and the corner panel.
A
Refrigerant piping of the main unit
B
Drain piping of the main unit
C
Corner panel
* Installation in any position is possible.
D
Position of the levers on the intake grille when sent from the factory.
* Although the clips can be installed in any of four positions.
E
Receiver (for SLP-2ALW)
 &KHFN
‡ 0DNH VXUH WKDW WKHUH LV QR JDS EHWZHHQ WKH XQLW DQG WKH JULOOH RU EHWZHHQ WKH JULOOH
and the surface of the ceiling. If there is any gap between the unit and the grille, or
between the grille and the surface of the ceiling, it may cause dew to collect.
‡ 0DNH VXUH WKDW WKH ZLUHV KDYH EHHQ VHFXUHO\ FRQQHFWHG
'RZQZDUG ƒ
'RZQZDUG ƒ
25