Download Print this page

Mitsubishi Electric PLFY-P-VCM-E Installation Manual

Air-conditioners for building application indoor unit
Hide thumbs Also See for PLFY-P-VCM-E:

Advertisement

Quick Links

Air-Conditioners For Building Application
INDOOR UNIT
PLFY-P·VCM-E

INSTALLATION MANUAL

For safe and correct use, please read this installation manual thoroughly before installing the air-conditioner
unit.
INSTALLATIONSHANDBUCH
Zum sicheren und ordnungsgemäßen Gebrauch der Klimaanlage das Installationshandbuch gründlich
durchlesen.
MANUEL D'INSTALLATION
Veuillez lire le manuel d'installation en entier avant d'installer ce climatiseur pour éviter tout accident et vous
assurer d'une utilisation correcte.
INSTALLATIEHANDLEIDING
Voor een veilig en juist gebruik moet u deze installatiehandleiding grondig doorlezen voordat u de airconditioner
installeert.
MANUAL DE INSTALACIÓN
Para un uso seguro y correcto, lea detalladamente este manual de instalación antes de montar la unidad de
aire acondicionado.
MANUALE DI INSTALLAZIONE
Per un uso sicuro e corretto, leggere attentamente questo manuale di installazione prima di installare il condizionatore
d'aria.
E°XEIPI¢IO O¢H°IøN E°KATA™TA™H™
°È· ·ÛÊ¿ÏÂÈ· Î·È ÛˆÛÙ‹ ¯Ú‹ÛË, ·Ú·Î·Ï›ÛÙ ‰È·‚¿ÛÂÙ ÚÔÛ¯ÙÈο ·˘Ùfi ÙÔ ÂÁ¯ÂÈÚ›‰ÈÔ ÂÁηٿÛÙ·Û˘
ÚÈÓ ·Ú¯›ÛÂÙ ÙËÓ ÂÁηٿÛÙ·ÛË Ù˘ ÌÔÓ¿‰·˜ ÎÏÈÌ·ÙÈÛÌÔ‡.
MANUAL DE INSTALAÇÃO
Para segurança e utilização correctas, leia atentamente este manual de instalação antes de instalar a unidade
de ar condicionado.
MONTAJ ELK‹TABI
Emniyetli ve do¤ru biçimde nas›l kullan›laca¤›n› ö¤renmek için lütfen klima cihaz›n› monte etmeden önce bu
elkitab›n› dikkatle okuyunuz.
РУКОВОДСТВО ПО УСТАНОВКЕ
Для осторожного и правильного использования прибора необходимо тщательно ознакомиться с данным
руководством по установке до выполнения установки кондиционера.
For use with the R410A, R407C & R22
Bei Verwendung von R410A, R407C & R22
A utiliser avec le R410A, R407C et le R22
Bij gebruik van R410A, R407C & R22
Para utilizar con el R410A, R407C y el R22
Uso del refrigerante R410A, R407C e R22
FOR INSTALLER
FÜR INSTALLATEURE
POUR L'INSTALLATEUR
VOOR DE INSTALLATEUR
PARA EL INSTALADOR
PER L'INSTALLATORE
°π∞ ∞À∆√¡ ¶√À ∫∞¡∂π ∆∏¡ ∂°∫∞∆∞™∆∞™∏
PARA O INSTALADOR
MONTÖR ‹Ç‹N
ДЛЯ УСТАНОВИТЕЛЯ
°È· ¯Ú‹ÛË Ì ٷ R410A, R407C Î·È R22
Para utilizaçao com o R410A, R407C e o R22
R410A, R407C ve R22 ile beraber kullanmak için
Для использования с моделями R410A, R407С и R22
English
Deutsch
Français
Nederlands
Español
Italiano
∂ÏÏËÓÈο
Português
Türkçe
Русский

Advertisement

loading

Summary of Contents for Mitsubishi Electric PLFY-P-VCM-E

  • Page 1: Installation Manual

    Air-Conditioners For Building Application INDOOR UNIT PLFY-P·VCM-E For use with the R410A, R407C & R22 °È· ¯Ú‹ÛË Ì ٷ R410A, R407C Î·È R22 Bei Verwendung von R410A, R407C & R22 Para utilizaçao com o R410A, R407C e o R22 A utiliser avec le R410A, R407C et le R22 R410A, R407C ve R22 ile beraber kullanmak için Bij gebruik van R410A, R407C &...
  • Page 2: Table Of Contents

    • If the air conditioner is installed in a small room, measures must be taken to • Use only accessories authorized by Mitsubishi Electric and ask the dealer or prevent the refrigerant concentration from exceeding the safety limit even if an authorized technician to install them.
  • Page 3: Installing The Indoor Unit

    2. Installing the indoor unit 2.2. Ceiling openings and suspension bolt installation (mm) locations (Fig. 2-2) • Using the installation template (top of the package) and the gauge (supplied as an accessory with the grille), make an opening in the ceiling so that the main unit can be installed as shown in the diagram.
  • Page 4: Refrigerant Pipe And Drain Pipe

    2. Installing the indoor unit 2.5. Unit suspension procedures (Fig. 2-5) Suspend the main unit as shown in the diagram. 1. In advance, set the parts onto the suspension bolts in the order of the washers (with insulation), washers (without insulation) and nuts (double). Min.
  • Page 5 3. Refrigerant pipe and drain pipe B Refrigerant pipe sizes & Flare nut tightening torque R407C or R22 R410A Flare nut O.D. Liquid pipe Gas pipe Liquid pipe Gas pipe Tightening Tightening Tightening Tightening Liquid Pipe size Pipe size Pipe size Pipe size torque torque...
  • Page 6: Electrical Work

    4. Electrical work 4.1. Indoor unit (Fig. 4-1) 1.Remove 2 screws to detach the electric component cover. 2.Route each cable through the wiring intake into the electric component box. (Pro- cure power supply cable and control cable locally.) 3.Securely connect the power supply cable and control cable to the terminal blocks. 4.Secure the cables with clamps outside the electric component box.
  • Page 7: Installing The Grille

    4. Electrical work 4.4. Sensing room temperature with the built-in sen- sor in a remote controller If you want to sense room temperature with the built-in sensor in a remote controller, set SW1-1 on the control board to “ON”. The setting of SW1-7 and SW1-8 as neces- sary also makes it possible to adjust the air flow at a time when the heating ther- mometer is OFF.
  • Page 8 5. Installing the grille 5.3. Installing the grille (mm) • Please pay attention because there is a restriction in the attachment position of the grille. 5.3.1. Preparations (Fig. 5-5) • Install the two enclosed screws with washer in the main unit (at the corner refriger- ant pipe area and at the opposite corner) as shown in the diagram.
  • Page 9: Test Run (Fig. 6-1)

    5. Installing the grille 5.5. Installing the intake grille (Fig. 5-11) • Perform the procedure that is described in “5.2 Preparing to attach the grille” in reverse order to install the intake grille and the corner panel. A Refrigerant piping of the main unit B Drain piping of the main unit C Corner panel * Installation in any position is possible.
  • Page 10 This product is designed and intended for use in the residential, commercial and light-industrial environment. • Low Voltage Directive 73/23/ EEC The product at hand is • Electromagnetic Compatibility Directive 89/ based on the following 336/ EEC EU regulations: Please be sure to put the contact address/telephone number on this manual before handing it to the customer.

This manual is also suitable for:

City multi plfy-p-vcm-e