4 SETUP AND PREPARATION BEFORE OPERAATION
POINT
(1) Set the offset and gain values in the actual usage state.
(2) The offset and gain values are stored on E
are not cleared at power-off.
(3) Shorting the TEST terminals to enter the test mode and executing initial settings
will start D/A conversion on all channels. To judge the test mode, use the test
mode flag as an interlock.
(4) Make offset/gain setting within the range indicated in POINT of Section 3.3.1
and Section 3.3.2. If setting is made outside this range, the maximum
resolution/accuracy may not fall within the performance specifications range.
(5) When making offset/gain setting (in the test mode), set all channels to any of
"user range settings 1 to 3".
Setting any other range will result in an error and flicker the "RUN" LED at 0.1s
intervals.
Refer to Section 3.6.4 for output range setting.