Meaning Of Status Led And Single-Character Display (Scd) - IBM LTO Ultrium 4 Installation And User Manual

Half high tape drive
Table of Contents

Advertisement

Table 3. Meaning of status LED and single-character display (SCD)
Indicator
Single-
"Ready" LED
character
(green)
display (red)
"1"
Off
"1" Flashing
Flashing
"2"
Off
"3"
Off
"4"
Off
"5"
Off
"6"
Off
5
"6" or "7"
Off
5
"7"
Off
"8"
Off
"A"
Off
7
"C"
Off or On
7
"C"
Flashing
5
"F"
Off
"H"
Off
5
"J"
Off
5
"P"
Off
Segments
Off
2
Flashing
Off
Both LEDs Flashing
Together
9
On
Flashing
Rapidly
10
3.0 sec On
3.0 sec On
7
Off or "C"
Off
7
Off or "C"
Flashing
7
Off or "C"
On
7
Off or "C"
Flashing
12
LTO Ultrium 4 Half High Tape Drive
"Fault" LED
(amber)
On
Maximum operating temperature
exceeded
On
Self test is in progress
On
Input voltage failure
2
Flashing
Drive firmware failure
2
Flashing
Drive firmware or hardware failure
2
Flashing
Unrecoverable drive failure
On
Drive or media failure
On
Cleaning cartridge loaded, clean
failed
On
Media error
Flashing
SAS interface failure
On
Recoverable drive error
7
On
Cleaning is required (clean bit is
set)
Off
Cleaning in progress
On
Incorrect firmware update tape used Replace firmware update tape.
Flashing
Firmware update failed
On
Incorrect (incompatible) media
On
Media is write-protected (and write
operation was attempted)
Off or On
Power-on self-test in progress
Firmware update is in progress
On
Drive is in service mode
2
10
10
3.0 sec On
After power-on self-test and drive
reset
7
Off or On
No cartridge is loaded
2
7
Off or On
Cartridge is loading or unloading
7
Off or On
Cartridge is loaded, no activity
7
Off or On
Data cartridge is loaded, activity
Status condition
1
3
4
6
8
10
Action
Reduce drive temperature.
Wait for test to complete.
Check input power
connections.
Update to latest level
firmware.
3
Clean drive and/or replace
cartridge if needed. Retry
operation. If it fails again, see
SK/ASC/ASCQ in User's
Guide for action.
Replace cleaning cartridge,
which may have expired.
Replace cartridge. Possible
expired cleaning cartridge.
Check SAS cable & connector.
Clean drive & retry operation.
Clean drive as soon as
possible.
Wait for cleaning to complete.
Retry firmware update
operation.
Insert correct media type.
Use media not
write-protected.
Wait 30-60 seconds.
Wait for update to complete.