Connect and test power to the drive

About this task
The drive does not contain its own power source; it must be powered externally.
To connect and test power to the drive, complete the following steps:
1. Ensure that the enclosure (or unit that supplies power to the drive) is powered
2. Ensure that the power cord is disconnected from both the enclosure and the
3. Connect the enclosure internal power cable to the power connector on the drive
4. Connect the power cord to the enclosure and to the electrical outlet.
5. Review the location of the single-character display (SCD) and the status LED in
8
LTO Ultrium 4 Half High Tape Drive
2.5mm (0.10 in.)
MAXIMUM Penetration
Depth From OUTSIDE
of Drive
off.
power outlet.
(see 2 in "Rear view of the drive" on page 2).
Figure 2 on page 2. To ensure that the drive is receiving power, watch for the
following while turning on the power to the enclosure:
v During the power-on/initialization and POST (Power-On Self Test), the SCD
briefly displays
8
, then becomes blank (not lit) when POST is complete and there are no POST
errors. If a POST error has been detected, an error code will be displayed in
the SCD and the status LED will flash amber.
Lower Side Mounting Holes
Drive
5.0mm (0.20 in.)
MAXIMUM Penetration
Depth From OUTSIDE
of Drive
Air Intake Area