6-5. Enclosure design guide to prevent dust (Indoor)
• Glass
Protected with Thermal Tempered Glass in Screen Area.
Glass shall be AR (anti-reflection) or AG (anti-glare) coated.
• FAN and Temperature Control
FAN is required to intake Air cool ambient air into the Enclosure and Circulate Air inside.
Inside temperature must be maintained between 0°C and 40°C (by Fan Speed control or ETC)
• Filter
Filter is Attached to Air-intake hole of Enclosure and shall be checked to clean at least 3-month
carefully choose the appropriate filter according to the installation environment.
• Wiring (Power, Signal Cable)
The Hole, such as power cable and signal cable, Must be sealed to prevent the dust
• Enclosure
The enclosure shall be fabricated from aluminum, powder coated steel, or stainless steel
and have structural elements to guide air flow. As shown in the figure below
Recommend to design the enclosure to meet with IP rating
IP
Enclosure
Must maintain 0 ~ 40 °c
inside the Enclosure
Protective Glass
(Tempered vandal glass)
Air flow gap 25~50mm
NOTE
To prevent dust, filter should be attached in the ventilation holes and bottom of the enclosure
Airport / Bus stop / Railroad station / Mall
5 X
Subway
6 X
Ventilation Holes
Filter (to prevent dust)
WALL
20cm
Cooling FAN
Filter (to prevent dust)
68