EQ-500

SPECIFICATIONS

Type
Item
Model No.
Adjustable range (Note 1) (Note 2)
0.2 to 2.5 m
Sensing range (at maximum setting distance) (Note 2)
0.1 to 2.5 m
Hysteresis
Supply voltage
AC: 4 VA or less
Power / Current consumption
DC: 3 W or less
Relay contact 1a
Output
Output operation
Short-circuit protection
Response time
20 ms or less (For EQ-50 T depends on the setting timer period) 2 ms or less (For EQ-51 T depends on the setting timer period)
Operation indicator
Stability indicator
Distance adjuster
Sensing mode
Timer function
Automatic interference prevention function
Protection
Ambient temperature
Ambient humidity
Ambient illuminance
Voltage withstandability
2,000 V AC for one min. among supply terminals, non-supply metal parts and relay contact output terminals, 1,000 V AC for one min. between relay contacts
Insulation resistance
100 M , or more, with 500 V DC megger among supply terminals, non-supply metal parts and relay contact output terminals as well as between relay contacts
Vibration resistance
Shock resistance
Emitting element
Receiving element
Material
Connection method
Cable
Cable length
Weight
Accessory
Notes: 1)
The adjustable range stands for the maximum sensing range which can be set with the distance adjuster. The sensor can also detect an object 0.1 m
0.328
ft, or more, away.
2)
The adjustable range and the sensing range are specified for white non-glossy paper (200
3)
Note that the detection may be unstable depending on the mounting conditions or the sensing object. In the state that this product is mounted, be sure
to check the operation with the actual sensing object. Refer to 'Automatic interference function' (p.8) of 'PRECAUTIONS FOR PROPER USE' for
details.
198
Multi-voltage
With timer
EQ-501
EQ-501T
EQ-502
0.656 to 8.202 ft
0.2 to 1.0 m
0.328 to 8.202 ft
0.1 to 1.0 m
24 to 240 V AC
10 % or 12 to 240 V DC
Ripple P-P 10 % or less
AC: 5 VA or less
AC: 4 VA or less
DC: 4 W or less
DC: 3 W or less
Switching capacity: 250 V AC 3 A (resistive load)
30 V DC 3 A (resistive load)
Electrical life: 100,000 or more switching operations
(switching frequency 1,200 operations/hour)
Mechanical life: 50 million or more switching operations
(switching frequency 18,000 operations/hour)
Green LED (lights up under stable operating condition)
Incorporated
with variable
(0.1 to 5 sec.)
ON-delay /
OFF-delay timer
20 to 55 C
4 to
131 F
(No dew condensation or icing allowed), Storage:
Sunlight: 10,000 ?x at the light-receiving face, Incandescent light: 3,000 ?x at the light-receiving face
10 to 55 Hz frequency, 1.5 mm
2
500 m/s
acceleration (50 G approx.) in X, Y and Z directions for three times each
Enclosure: ABS, Front cover: Polycarbonate, Display cover: Polycarbonate
Suitable for round cable "9 to"11 mm
Extension up to total 100 m
100 g approx.
With timer
EQ-502T
EQ-511
0.656 to 3.281 ft
0.2 to 2.5 m
0.328 to 3.281 ft
0.1 to 2.5 m
10 % or less of operation distance
10 %
12 to 24 V DC
AC: 5 VA or less
DC: 4 W or less
NPN open-collector transistor
Maximum sink current: 100 mA
Applied voltage: 30 V DC or less (between output and 0 V)
Residual voltage: 1 V or less (at 100 mA sink current)
PNP open-collector transistor
Maximum source current: 100 mA
Applied voltage: 30 V DC or less (between output and
Residual voltage: 1 V or less (at 100 mA source current)
Switchable either Detection-ON or Detection-OFF
Orange LED (lights up when the output is ON)
2-turn mechanical adjuster with indicator
Incorporated
with variable
(0.1 to 5 sec.)
ON-delay /
OFF-delay timer
Incorporated (Note 3)
IP67 (IEC)
35 to 85 % RH, Storage: 35 to 85 % RH
0.059 in
amplitude in X, Y and Z directions for two hours each
Infrared LED (modulated)
2-segment photodiode
Screw-on terminal connection
"0.354 to "0.433 in
328.084 ft
is possible with 0.3 mm
Adjusting screwdriver: 1 pc.
200 mm
08/2005
DC-voltage
With timer
EQ-511T
EQ-512
0.656 to 8.202 ft
0.2 to 1.0 m
0.656 to 3.281 ft
0.328 to 8.202 ft
0.1 to 1.0 m
0.328 to 3.281 ft
10 % Ripple P-P 10 % or less
45 mA or less
0.4 V or less (at 16 mA sink current)
0.4 V or less (at 16 mA source current)
Incorporated
Switchable either BGS or FGS function
Incorporated
with variable
(0.1 to 5 sec.)
ON-delay /
OFF-delay timer
30 to
70 C
22 to
2
, or more, cabtyre cable
85 g approx.
7.874
7.874
in) as the object.
With timer
EQ-512T
V)
Incorporated
with variable
(0.1 to 5 sec.)
ON-delay /
OFF-delay timer
158 F

Advertisement