Whisper Power m-sq25 User Manual page 37

Marine diesel generating set 230/400v / 50hz
Hide thumbs Also See for m-sq25:
Table of Contents

Advertisement

3
To take the generating set out of the canopy all hose
and cable connections have to be taken off. The set is
fixed to its base by four rubber mountings and can be
loosened by removing the four nuts from the bolts of
these mountings. The easiest way to get the
generator out of its capsule is by lifting the set with the
aid of the lifting eyes
4
Taking the generator set from its mounting, or to
replace a mounting can be done according to the
drawing below
Fig. 32 Exploded view rubber mountings
EN / M-SQ20 / 25 / November 2010
5
Reassembling the generating set one should take
care of alignment, cleaning the surfaces between
engine and alternator and tighten the bolts crosswise
and gradually.
6
Test the generating set first outside its capsule and
check very carefully for leakages before putting it
back in its enclosure.
TROUBLE SHOOTING
37

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

M-sq20

Table of Contents