To change the Ethernet OAM operating mode on an Ethernet OAM-enabled port, you need to first
disable Ethernet OAM on the port.

Configuring Link Monitoring

After Ethernet OAM connections are established, the link monitoring periods and thresholds configured
in this section take effect on all Ethernet ports automatically.
Configuring Errored Symbol Event Detection
An errored symbol event occurs when the number of detected symbol errors over a specific detection
interval exceeds the predefined threshold.
Follow these steps to configure errored symbol event detection:
To do...
Enter system view
Configure the errored symbol
event detection interval
Configure the errored symbol
event triggering threshold
Configuring Errored Frame Event Detection
An errored frame event occurs when the number of detected error frames over a specific interval
exceeds the predefined threshold.
Follow these steps to configure errored frame event detection:
To do...
Enter system view
Configure the errored frame
event detection interval
Configure the errored frame
event triggering threshold
Use the command...
system-view
oam errored-symbol period
period-value
oam errored-symbol threshold
threshold-value
Use the command...
system-view
oam errored-frame period period-value
oam errored-frame threshold
threshold-value
1-7
Remarks
Optional
1 second by default
Optional
1 by default
Remarks
Optional
1 second by default
Optional
1 by default