PC auto setting
Sets the operational mode of the automatic position
adjustment in the [Position] menu.
[Off]:
Automatic position adjustment starts when <AUTO
SETUP> is pressed on the remote control or
automatic position adjustment is executed from the
[Position] menu.
[On]:
Other than remote control or menu operation,
automatic position adjustment starts:
When the display power is turned ON.
When the input signal is switched.
Off-timer function
Enables / disables Off timer function.
[Enable]:
Enables the [Off-timer function].
[Disable]:
Disables the [Off-timer function].
Note
When [Disable] is set, the Off-timer is cancelled.

Initial startup

Sets the power mode of the unit for when the power
recovers from failure or after plugging off and in again.
[Last memory]:
Power returns in as the same state as before the
power interruption.
[On]:
Power returns in power On.
(Power Indicator: green)
[Standby]:
Power returns in standby mode.
(Power Indicator: red/orange)
Note
When using multiple displays, [Standby] is preferred
to be set in order to reduce a power load.
Startup logo
Sets to display / not to display the Panasonic logo on the
screen when the display is turned on.
[Off]:
Panasonic logo is not displayed.
[On]:
Panasonic logo is displayed.
66
English
Display ID
Sets ID number when controlling the Display with
[Controller ID function] and [Serial ID function].
0 - 100 (Standard value: 0)
Controller ID function
Enables/Disables the ID remote control function.
To operate this function, please purchase ID remote
controller sold separately. (see page 90)
[Off]:
Disables the ID remote control function. (Can be
operated as normal remote control.)
[On]:
Enables the ID remote control function.
Effective on switching to [On].
Note
To use the ID remote control function, setting ID
numbers both for the remote control and for the
display unit is required.
For ID number setting for the remote control
and display unit, see page 90 and [Display ID]
respectively.
Note
About how to reset the settings to defaults:
"Initialization" (see page 69)
Serial ID function
Set to control external control with the PC connected to
SERIAL terminal according to the Display's ID number
(Panel ID).
[Off]:
Disables external control by the ID.
[On]:
Enables the external control by the ID.
Serial response(ID all)
Sets whether to respond to the command or not, when
serial command of ID No "0" is received.
[Off]:
Does not respond.
[On]:
Responds.