Information Timing - Panasonic TH-55SF1HU Operating Instructions Manual

Hide thumbs Also See for TH-55SF1HU:
Table of Contents

Advertisement

Serial daisy chain position
Set the first and last terminals in the chain when the
SERIAL IN/OUT terminal of this unit is connected using
a daisy chain scheme.
[---]:
When controlling this unit alone with serial control,
or connecting at a position other than the first and
last terminals in a daisy chain
[Top]:
When connecting at the first terminal in a daisy
chain
[End]:
When connecting at the last terminal in a daisy
chain
LAN control protocol
Select the LAN control protocol.
[Protocol 1]:
Control with the Panasonic Display sequence.
[Protocol 2]:
Control with the sequence that is compatible with
Panasonic Projector.
Note
For PJLink and WEB browser control, the operation is
possible regardless of the setting.
When performing the command control with TCP/IP,
select [Protocol 1].
When operating the "Early Warning Software" or
"Multi Monitoring & Control Software", select [Protocol
2].

Information timing

Set up the informing manner for no signal or
temperature rising.
During RS-232C controls:
Warning or error message sent from the display
automatically.
During LAN controls:
Acquire the warning or error message from the
display.
1
Select the item with
Select the set point with
Information timing
No signal warning
No signal warning timing
No signal error
No signal error timing
Temperature warning
.
.
On
5min
On
10min
On
[No signal warning]
When set to [On], the display sends out the no signal
warning.
[No signal warning timing]
Set up the detecting time for no signal warning.
(Range: 01 - 60, Interval: 1 minute)
[No signal error]
When set to [On], the display sends out the no signal
error.
[No signal error timing]
Set up the detecting time for no signal error.
(Range: 01 - 90, Interval: 1 minute)
The warning of [No signal warning] and the error
of [No signal error] are not sent when the no signal
state is detected through any of the following
functions:
[No signal power off], [HDMI1 power management],
[HDMI2 power management], [DIGITAL LINK
power management], [DVI-D power management],
[PC power management] (see page 50)
Setting Example:
[No signal warning timing]: 5 minutes
[No signal error timing]: 10 minutes
Note
The [No signal error timing] cannot be set shorter
than [No signal warning timing].
[Temperature warning]
When set to [On], the display sends out the warning
message.
Note
With the USB input, the unit determines no signal
is present when the USB memory is not connected
to the USB terminal.
67
English