Preamble Congratulations on your purchase of one of the most powerful hand-held scanner for decoding direct marked 2D-Codes. This document is intended for information about the handling and use of the HS 6508 from Leuze electronic. The most important information that is needed for operation is explained. Furthermore, even explains the main types of connections and presented the programming using the codes.
Page 3
OU WILL FIND FURTHER ADJUSTMENT IN THE ..............................19 ROUBLESHOOTING OVERVIEW OF TYPES AND ACCESSORIES ....................... 20 ........................21 ONNECTION TO EUZE MULTINET PLUS MA 200 ....................21 ONNECTING SEVERAL FIELDBUSES WITH Quick Start Guide HS 6578 Leuze electronic Page...
Delivery HS 6578 xx 1. Handheld scanner HS 6578 DPM 2. Battery 3. Leaflet for Quick Start Parts The model designation is on the Top panel Battery References to standards are located on the bottom side Quick Start Guide HS 6578...
Delivery Base f. HS 6578 1. Base-Station for Handheld scanner HS 6578 2. Rubber feet (4 pcs.) Parts Front Pairing Barcode Mounting Screw hole Charging-/Communication Contacts Back Cable Hook Mounting Screw hole Mounting Screw hole Host port Power Port Label with Type...
- please refer to the instruction manual of your computer. Connect the cable to the Base f. HS 6578 The following illustrations show the steps required to install the cable at the base station are shown, which are described below.
Testing the Scanner The adjacent bar code (code 39) is for testing the scanner, The module size is 0.5 mm (20 mil) Quick Start Guide HS 6578 Leuze electronic Page...
Technical Data For the technical Data please refer the data sheet of the HS 6578 Pinning of the cables KB 232-1 HS65x8 Part-No. 50120436 Coiled cable with a length of 2.8 meters (Stretched). Pinning 9 pin D-sub connector (female) for cable CBA-R36-C09ZAR...
Note: Note that the real reading distances are still influenced by factors such as labeling, quality printing, scanning angle, printing contrast etc. and therefore may differ from those given here reading distances. Quick Start Guide HS 6578 Leuze electronic Page...
A second option is to configure the hand scanner with USB and RS232 interface using the PC program ESP. This program lets you download and install from our website www.leuze.de. With the program settings can be made and transmitted to the hand-held scanner. The configuration can also be stored, so that later it can be reused.
The pin assignment of the 9 pin D-sub connector (female) can be found on page 10 RS232-Interface Connection cable Please connect the HS 6578 in accordance with the illustration. RS 232 with 9600 Baud, 8 Data bit, 1 Stopbit, No Parity, no Prefix and Postfix...
HS 6578 at MA 200i RS 232-Data Transmission with 9600 Baud, 8 Data bit, 1 Stopbit, No Parity, Postfix CR/LF. Required parts: 50120442 HS 6578 DPM 50120436 KB 232-2 HS65x8 50120446 Base f. HS 6578 50120430 NT Base 6578 50113397...
HS 6578 at MA 21 RS 232-Data Transmission with 9600 Baud, 7 Data bit, 1 Stopbit, Parity Even, Postfix CR/LF. Required parts: 50120442 HS 6578 DPM 50120436 KB 232-2 HS65x8 50120446 Base f. HS 6578 50120430 NT Base 6578 50035421...
HS 6578 at PS2-Interface In this chapter, the operation of the HS 6578 in keyboard wedge mode is described. In this mode, a PC keyboard is emulated. The downloaded data is written directly to the currently active program. Thus, the data can be processed in all standard programs.
HS 6578 at USB-Interface (Keyboard-Emulation) In this chapter, the operation of the HS 6578 in USB keyboard wedge mode is described. In this mode, a PC keyboard is emulated. The downloaded data is written directly to the currently active program. Thus, the data can be processed in all standard programs.
HS 6578 at USB-Interface (COM-Port-Emulation) In this chapter, the operation of the HS 6578 is described as a serial interface to USB. In this mode, a COM port is emulated. The scanned data is sent to a new COM port. The driver allows you to emulate this COM interface, you can download on our website www.leuze.de.
The check digit validation will be switched off again, please scan code. This check digit should be also transferred is to scan the following bar code. The check digit is not transferred, please scan code. Quick Start Guide HS 6578 Leuze electronic...
If the data can be transmitted, but an enter character (or CR / LF or newline) is missing, you can with the following codes it can be added. Scan all codes in the printed order please. Quick Start Guide HS 6578 Leuze...
Suspect the problem in the quality of the label, check the reading readiness with a qualitatively good label. 9. Should the problems be now, still not resolved, contact Leuze electronic in conjunction. Quick Start Guide HS 6578...
Base-Station for Communication und Charging 007WR Schnittstellen/Interfaces: PS2; USB; TTL RS232 Bluetooth V2.1 50120430 Netzteil für Base f. HS 6578 50-14000-26 Power supply for Base f. HS 6578 9 Volt DC) KB USB-1 HS 65x8 50120432 USB-Kabel (gerade 2,8m) USB-cable (straight 2,8 m) CBA-U12-C0...