We congratulate you on the purchase of one of the most powerful hand-held scanners. This document is intended to provide information on the handling and use of the IT 6320 produced by Leuze electronic. It includes explanations of the most important information necessary for operation. In addition, the most important connection types are explained and information is provided on programming with the aid of codes.
Leuze electronic Scope of delivery • IT 6320 DPM Part No. 50105382 1. Hand-held scanner 6320 IDP-351S 2. Rechargeable battery (installed) 3. CD-ROM • ST 2020 Part No. 50103990 1. Base station ST 2020-5B Type designation Type designation An overview of the types can be found on page 18...
Leuze electronic Installation Switching off the computer Information on switching off and shutting down the connected computer - which must always be performed before connecting peripheral devices, such as a scanner - can be found in the appropriate operating instructions for your computer.
Leuze electronic Specifications The technical data can be found in the data sheet for the IT 6320 / ST 2020. Pin assignments of the connection cable TTL-RS 232 cable/PIN9 IT 4xxx Part No. 50104586 Pin assignments of the 9 pin D-sub socket (female) for cable 42203758-03...
"6300 Series Setup Tool" PC program. You can download and install this program from our homepage at www.leuze.de. The program can be used to make settings and transfer them to the hand-held scanner. The configuration can also be stored so that the same configuration can be reused at a later time.
With TTL-RS 232 cable/PIN9 IT 4xxx Part No. 501 04586 Please connect the IT 6320 + ST2020 acc. to the adjacent figure. Required parts: 501 05 382 IT 6320 DPM 351S 501 03 990 ST 2020 501 04 586 Cable TTL-RS232/PIN9...
Leuze electronic Configuration for the Leuze standard protocol Leuze standard protocol: RS 232 with 9600 baud, 8 data bits, 1 stop bit, no parity, prefix STX and postfixes CR/LF Factory setting Return the IT 6320 to the base station to apply the settings. This procedure is concluded with audible confirmation signals.
Page 10
IT 6320 on MA 41 DP-K or MA 41 IS RS 232 transmission with 9600 baud, 8 data bits, 1 stop bit, no parity, postfixes CR/LF. Required parts: 501 05 382 IT 6320 DPM 351S 501 03 990 ST 2020 501 04 586...
Page 11
Leuze electronic Configuration Factory setting Return the IT 6320 to the base station to apply the settings. This procedure is concluded with audible confirmation signals. To configure the device, please scan the codes in the specified order. The read operation is confirmed by an audible signal from the IT 6320.
IT 6320 to MA 21 RS 232 transmission with 9600 baud, 7 data bits, 1 stop bit, even parity, postfixes CR/LF. Required parts: 501 05 382 IT 6320 DPM 351S 501 03 990 ST 2020 501 04 586 Cable TTL-RS232/PIN9...
Page 13
Leuze electronic Configuration Factory setting Return the IT 6320 to the base station to apply the settings. This procedure is concluded with audible confirmation signals. To configure the device, please scan the codes in the specified order. The read operation is confirmed by an audible signal from the IT 6320.
The data which are read in are written directly to the currently activated program. Thus, the data can be processed further in all standard programs. Required parts: 501 05 382 IT 6320 DPM 351S 501 03 990 ST 2020 501 03 989...
The data which are read in are written directly to the currently activated program. Thus, the data can be processed further in all standard programs. Required parts: 501 05 382 IT 6320 DPM 351S 501 03 990 ST 2020 501 03 989...
The data which are read in are sent to a new COM interface. The driver with which you emulate this COM interface can be found on the CD-ROM or can be downloaded from our homepage at www.leuze.de. Thus, the data can be processed further in programs which expect data via COM interfaces.
Page 17
If you suspect that the problem lies with the quality of the label, check the read readiness with a label of relatively good quality. 8. If the problems are still not corrected, please contact Leuze electronic. Short instructions IT 6320...
Leuze electronic Type overview IT Reihe / IT series Part No. Bezeichnung/Description Schnittstelle/Interface Bild/Picture Industrie-Handleser (IP 54) für direktmarkierte 2D- Codes Industrial hand-held scanner (IP 54) for DPM 2D-code 50105382 IT 6320 IDP 351S Bluetooth Basis-Station mit Kommunikation-/ und Ladefunktion...
Page 19
Leuze electronic Short instructions IT 6320 Leuze electronic Page...
Leuze electronic Connecting to Leuze multiNet Plus • MA 21 100 Interface converter / multiNet slave Part No. 500 30 481 • KB 021 Z Connection cable MA 21 to IT 4600/4800 Part No. 500 35 421 Connecting to Profibus •...
Leuze electronic Codes for fast configuration Reset scanner to Factory setting Reboot scanner Disconnect Bluetooth connection Only activate setup 1 (default) Only activate setup 2 Only activate setup 3 Only activate setup 4 Reset base station to factory settings Activate USB keyboard...
Page 23
Leuze electronic 7 data bits, even parity, 1 stop bit 7 data bits, no parity, 1 stop bit 7 data bits, odd parity, 1 stop bit 7 data bits, even parity, 2 stop bits 7 data bits, no parity, 2 stop bits...
Page 24
Leuze electronic Hardware handshake RTS/CTS off (default) Hardware handshake RTS/CTS on Keyboard layout USA (default) Keyboard layout Germany Keyboard layout France Leuze electronic GmbH+Co.KG Postfach 1111 In der Braike 1 73277 Owen/ Teck, Germany Tel +49 (07021) 573-0 Fax +49 (07021) 573-199 E-mail: info@leuze.de...