Exchanging a Fan-and-Power-Supply Assembly

You can exchange a faulty fan-and-power-supply assembly if:
v You have a correct spare fan-and-power-supply assembly or fan assembly.
v Another fan-and-power-supply assembly is still present in the 2104.
Note: If your 2104 contains just one fan-and-power-supply assembly (and one fan
Figure 33. A Fan-and-Power-Supply Assembly
You do not need to remove power from the 2104 when exchanging a
fan-and-power-supply assembly.

Before Exchanging a Fan-and-Power-Supply Assembly

v Check the lights on this fan-and-power-supply assembly ("Fan-and-Power-
assembly), refer to Expandable Storage Plus: 2104 Models DU3 and TU3 Service
Guide for more guidance about replacing the fan-and-power-supply
assembly.
Supply Assembly and Fan Assembly Lights and Switch" on page 9 describes
these lights and how to see them). Ensure that the DC On/Standby switch is set
to On.
If the CHK light is on, exchange the fan-and-power-supply assembly by using
the procedure in the following section.