8.5 Setting A larm Response A ctions
Purpose:
The alarm response actions will be activated when an exception occurs, including Full Screen Monitoring,
Audible Warning, Notify Surveillance Center, and Send Email.
F ull Screen Monitoring
When an alarm event (motion detection/tamper-proof/video loss detection) is triggered, the local monitor
(HDMI/VGA or BNC monitor) display in full screen the video image from the alarming channel configured for
full screen monitoring.
If alarms are triggered simultaneously in several channels, their full-screen images will be switched at an
interval of 10 seconds (default dwell time). A different dwell time can be set by going to Menu>
Configuration>Live View>Full Screen Monitoring Dwell Time.
Auto-switch will terminate once the alarm stops and you will be taken back to the Live View interface.
Note:
For motion detection alarm, you must select the channel(s) you want to make full screen monitoring
(Menu>Camera>Motion>Handling>Trigger Channel).
A udible W arning
Trigger an audible beep when an alarm is detected.
Notify Surveillance C enter
Sends an exception or alarm signal to remote alarm host when an event occurs. The alarm host refers to the PC
installed with Remote Client.
Note:
The alarm signal will be transmitted automatically at detection mode when remote alarm host is
configured. Please refer to Chapter 9.2.6 for details of alarm host configuration.
Send E mail
Send an email with alarm information to a user or users when an alarm event is detected.
Please refer to Chapter 9.2.10 for details of Email configuration.