Item No.
Setting: [DP] *: This setting is usually unnecessary.
U425
Display
Lead
Main Scan
Sub Scan
1. Measure the distance from the leading edge to the black belt (inside) of the original at A.
2. Enter the measured value using the cursor right/left keys or numeric keys in [Lead].
3. Measure the distance from the left edge to the black belt (inside) of the original at B.
4. Enter the measured value using the cursor right/left keys or numeric keys in [Main Scan].
5. Measure the distance from the black belt of leading edge (inside) to the black belt of trailing
edge (inside) of the original at C.
6. Enter the measured value using the cursor right/left keys or numeric keys in [Sub Scan].
7. Press the start key. The value is set.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Description
A value of length of detecting the lead-
ing edge.
A value of width of main scan.
A value of length of sub scan.
B
Original for adjustment (P/N: 302NM94330)
1-3-44
Description
Setting range
14.0 to 16.0
14.0 to 16.0
265.0 to 269.0
C
Figure 1-3-16
2PK/2PL/2PM/2PN-3
Initial setting
15.0
15.0
267.0
A

Hide quick links: