Kyocera ECOSYS M2030dn/PN Servlce Manual page 224

Hide thumbs Also See for ECOSYS M2030dn/PN:
Table of Contents

Advertisement

Emergency-UPDATE
If Safe Update is processed to the end, the firmware update is complete. In case the message below is indi-
cated, update the firmware after recovery with the steps below.
Note that this is unoperable when the device is operating normally.
Preparation
The USB memory must be formatted in FAT or FAT32 in advance.
Extract the main firmware to download from the file.
Rename the file which was extracted from the archive.
[DL_CTRL.2PK] to [KM_EMRG.2PK] : 3 in 1 model
[DL_CTRL.2PL] to [KM_EMRG.2PL] : 4 in 1 model
Copy the all extracted files to the root of the USB memory.
Procedure
1. Turn the main power switch off.
2. Insert the USB memory which contains
the firmware into the USB memory slot.
3. Turn the main power switch on.
4. Rewriting of the PWB software will start
for restoration.
"Emergency Update" is displayed on
the LCD of the operation panel.
5. "Completed" will be displayed when
rewriting is successful.
* : "Failed" will be displayed when rewrit-
ing is failed.
6. Turn the main power switch off.
7. Wait for several seconds and then
remove the USB memory from the USB
memory slot.
8. Extract the firmware to download from
the archive and copy to the root of the
formatted USB memory.
NOTE: Deletes the "ES_SKIP.on" file
When it is contained directly under the
USB memory.
9. Insert the USB memory in which the
firmware was copied in the USB mem-
ory slot.
10. Perform steps 3 to 7 on the previous
page.
11. Turn the main power switch on.
12. Perform maintenance item U000 (Print
a maintenance report) to check that the
version of ROM U019 has been
upgraded.
USB memory
Figure 1-6-2
1-6-2
2PK/2PL/2PM/2PN-5
FW-Update
Error
FFFF
USB memory slot

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents