Kyocera ECOSYS M2030dn/PN Servlce Manual page 136

Hide thumbs Also See for ECOSYS M2030dn/PN:
Table of Contents

Advertisement

Code
6000
Broken Fuser heater wire
The fuser temperature does not rise
after the Fuser heater has been
turned on.
6020
Abnormally high fuser thermistor
temperature
Fuser thermistor detects abnormally
temperature.
When the temperature of a fuser
thermistor detects 195 °C or more at
the time of heater OFF and 155 °C
or more.
6030
Broken fuser thermistor wire
Input from fuser thermistor is 0 (A/D
value).
Contents
Causes
Poor contact in
Reinsert the connector (See page 1-5-
the fuser therm-
32).
istor connector
terminals.
Poor contact in
Reinsert the connector (See page 1-5-
the Fuser heater
32).
connector termi-
nals.
Fuser thermistor
Replace the fuser unit (See page 1-5-
installed incor-
32).
rectly.
Fuser thermal
Replace the fuser unit (See page 1-5-
cutout triggered.
32).
Fuser heater
Replace the fuser unit (See page 1-5-
installed incor-
32).
rectly.
Broken Fuser
Replace the fuser unit (See page 1-5-
heater wire.
32).
Shorted fuser
Replace the fuser unit (See page 1-5-
thermistor.
32).
Defective control
Replace the control PWB (See page 1-
PWB.
5-37).
Poor contact in
Reinsert the connector (See page 1-5-
the fuser therm-
32).
istor connector
terminals.
Broken fuser
Replace the fuser unit (See page 1-5-
thermistor wire.
32).
Fuser thermistor
Replace the fuser unit (See page 1-5-
installed incor-
32).
rectly.
Fuser thermal
Replace the fuser unit (See page 1-5-
cutout triggered.
32).
Fuser heater
Replace the fuser unit (See page 1-5-
installed incor-
32).
rectly.
Broken Fuser
Replace the fuser unit (See page 1-5-
heater wire.
32).
1-4-14
2PK/2PL/2PM/2PN
Remarks
Check procedures
/corrective measures