(2) Detaching and refitting the DP drive PWB

Follow the procedure below to check or replace the DP drive PWB.
Procedure
1. Remove the DP rear cover.
(See page 1-5-51).
2. Remove eight connectors from the DP
drive PWB.
3. Remove the screw and then remove the
DP drive PWB.
4. Check or replace the DP drive PWB.
Refit all the removed parts.
Connector
Screw
DP drive PWB
1-5-52
2PK/2PL/2PM/2PN
DP drive PWB
Figure 1-5-78