Item No.
U403
Adjust Scanning Margin(Table)
Description
Adjusts margins for scanning the original on the contact glass.
Purpose
Make the adjustment if margins are incorrect.
Adjustment
1. Press the start key.
2. Press the system menu key.
3. Place an original and press the start key to make a test copy.
4. Press the system menu key.
5. Select the item to be adjusted.
Display
A Margin
B Margin
C Margin
D Margin
6. Change the setting value using the cursor left/right keys or numeric keys.
Increasing the value makes the margin wider, and decreasing it makes the margin narrower.
7. Press the start key. The value is set.
Caution
If the above adjustment does not optimize the margins, perform the following maintenance
modes.
U034
(P.1-3-17)
Completion
Press the stop key. The indication for selecting a maintenance item No. appears.
Description
Description
Scanner left margin
Scanner leading edge margin
Scanner right margin
Scanner trailing edge margin
Leading edge margin of the copy image
(4.0 +1.5/-1.0 mm)
Left margin of
the copy image
(2.5 +1.5/-2.0 mm)
Trailing edge margin of the copy image
(4.0 mm or less)
Figure 1-3-13
U402
(P.1-3-36)
1-3-37
Setting
range
0.0 to 10.0
0.0 to 10.0
0.0 to 10.0
0.0 to 10.0
Right margin of
the copy image
(2.5 +1.5/-2.0 mm)
U403
2PK/2PL/2PM/2PN-5
Initial
Change in
setting
value per step
2.0
0.5 mm
2.0
0.5 mm
2.0
0.5 mm
2.0
0.5 mm