• Expanded cyclic setting and number of link points
Expanded cyclic setting
Occupies 1 station
Occupies 2 stations
Occupies 3 stations
Occupies 4 stations
2.4

Communication function

2.4.1

Data transfer between 64CCL and master station

FX
/FX
/FX
main unit
3G
3U
3UC
M (auxiliary relay) etc.
M (auxiliary relay) etc.
D (data resister) etc.
D (data resister) etc.
Data is transferred using FROM/TO instructions via the buffer memory (or direct specification of buffer
memory) between the FX
M, R and D), and used in sequence programs.
Cyclic transmission and extended cyclic transmission are available between the master station and the
64CCL.
2.4.2
Summary of accessing the FX
mode) station.
The FX
/FX
3U
3UC
master / local station when GX Developer (Ver. 8.72A or later) is used.
Accessing permits write and read, verify, carry out device batch monitoring and complete device test.
16
CC-Link Ver.1.10
bit (RX)
bit (RY)
word (RWw)
word (RWr)
bit (RX)
bit (RY)
word (RWw)
word (RWr)
bit (RX)
bit (RY)
word (RWw)
word (RWr)
bit (RX)
128 points
bit (RY)
128 points
word (RWw)
word (RWr)
FX
extension bus
3U
BFM (Buffer memory)
TO instruction
RX: Remote input
FROM instruction
RY: Remote output
FROM instruction
RWw(Remote register)
TO instruction
RWr(Remote register)
/FX
/FX
PLC and the 64CCL. Data is replaced with internal devices (such as
3G
3U
3UC
3U
which is connected to the 64CCL can be accessed via CC-Link from QCPU (Q mode)
Single
Double
32 points
32 points
32 points
32 points
4 points
8 points
4 points
8 points
64 points
96 points
64 points
96 points
8 points
16 points
8 points
16 points
96 points
160 points
96 points
160 points
12 points
24 points
12 points
24 points
224 points
224 points
16 points
32 points
16 points
32 points
FX
-64CCL
3U
Cyclic,
Expanded cyclic
/FX
main unit from another station QCPU (Q
3UC
2 Specification and function
2.4 Communication function
CC-Link Ver.2.00
Quadruple
64 points
64 points
16 points
16 points
192 points
192 points
32 points
32 points
-
-
Q master station
CC-Link
RX: Remote input
RY: Remote output
RWw(Remote register)
RWr(Remote register)
Octuple
128 points
128 points
32 points