Com Port 1 Option Settings (Tpu2000R Only) [Catalog 588Xxx00-Xxx0 Or 588Xxx50-Xxx0]; Table 4-2. Winecp Communication Port Settings; Table 4-3. Com Port 1 And Com Port 2 Winecp Port Setting Options - ABB TPU2000 Technical Manual

Modbus/modbus plus/ modbus tcp/ip automation
Table of Contents

Advertisement

Table 4-2. WinECP Communication Port Settings

Option
COM PORT
BAUD RATE
Frame
Unit Address
NOTE : Bold indicates Selections Supported by WinECP and TPU2000/TPU2000R
COM Port 1 Option Settings (TPU2000R Only) [Catalog 588 XXX00-XXX0 or 588 XXX50-
XXX0]
If the unit does not have a front panel interface, the rear port is on the TPU2000R is active. The Configuration
screens through WinECP are shown in Figure 4-3 for reference.
configured via the front panel interface since this port is only active if the unit does not have a front panel
communication port interface (see Section 3 of this document for further information). The communication
protocol supported on this port is Standard Ten Byte Only.
Table 4-3 illustrates the port configuration options available for this COM Port 1. Figure 4-3 illustrates the
WinECP screen used to configure Communication Port 1 in the TPU2000R.

Table 4-3. COM Port 1 and COM Port 2 WinECP Port Setting Options

Option
BAUD RATE
Frame
TPU2000/2000R Modbus/Modbus Plus Automation Guide
Selection
COM 1
COM 2
COM 3
COM 4
300
1200
2400
4800
9600 (default setting)
19200
None – 8 – 1 (default setting)
None – 8 – 2
Even – 8 – 1
Odd – 8 – 1
Even – 7 – 1
None – 7 – 2
Odd – 7 – 1
1 – FFF (1 = Default)
Selection
300
1200
2400
4800
9600 (default setting)
19200
38400
None – 8 – 1 (default setting)
None – 8 – 2
Even – 8 – 1
Odd – 8 – 1
Even – 7– 1
None – 7 – 2
Odd – 7 – 1
Notes
Personal Computer Port Selection
for ECP to TPU2000 and TPU2000R
connection.
Baud Rates Offered for TPU
2000/2000R connection to the
WinECP RS232 port connection.
No Parity 8 Data Bits 1 Stop Bit
No Parity 8 Data Bits 2 Stop Bits
Even Parity 8 Data Bits 1 Stop Bit
Odd Parity 8 Data Bits 1 Stop Bit
Even Parity 7 Data Bits 1 Stop Bit
Even Parity 7 Data Bits 2 Stop Bits
Odd Parity 7 Data Bits 1 Stop Bit
Unit Address in HEX
The communication options may not be
Notes
Com Port Baud Rate Selections Via
WinECP or DOS ECP
No Parity 8 Data Bits 1 Stop Bit
No Parity 8 Data Bits 2 Stop Bits
Even Parity 8 Data Bits 1 Stop Bit
Odd Parity 8 Data Bits 1 Stop Bit
Even Parity 7 Data Bits 1 Stop Bit
Even Parity 7 Data Bits 2 Stop Bits
Odd Parity 7 Data Bits 1 Stop Bit
23