Rms Demand Current/Real And Reactive Power Values Block (24 Registers Defined); Table 5-22. To Be Named - ABB TPU2000 Technical Manual

Modbus/modbus plus/ modbus tcp/ip automation
Table of Contents

Advertisement

Register
Address
40546
KVar Hours A
40547
KVar Hours A
40548
KVar Hours B
40549
KVar Hours B
40550
KVar Hours C
40551
KVar Hours C
40552
3 Phase KWatts
40553
3 Phase KWatts
40554
3 Phase KVars
40555
3 Phase KVars
40556
3 Phase Kwatt Hours
40557
3 Phase Kwatt Hours
40558
3 Phase Kvar Hours
40559
3 Phase Kvar Hours
40560
3 Phase KVA
40561
3 Phase KVA
40562
System Frequency
40563
Spare (2 Winding Unit)
Power Factor (3 Winding Unit)
40564
Power Factor (2 Winding Unit)
Spare (3 Winding Unit)
40565
Signed Power Factor
40566
Power Factor Status

RMS Demand Current/Real and Reactive Power Values Block (24 Registers Defined)

Present RMS demand values are reported in Registers 40641 through 40664 for both the three and two winding
TPU2000R and the two Winding TPU2000.

Table 5-22. To Be Named

Register
40641
Demand Current Phase A
40642
Demand Current Phase A
40643
Demand Current Phase B
40644
Demand Current Phase B
40645
Demand Current Phase C
40646
Demand Current Phase C
40647
Demand Current Neutral
40648
Demand Current Neutral
40649
Demand kWatts Phase A
40650
Demand kWatts Phase A
40651
Demand kWatts Phase B
40652
Demand kWatts Phase B
40653
Demand kWatts Phase C
40654
Demand kWatts Phase C
40655
Demand kVars Phase A
TPU2000/2000R Modbus/Modbus Plus Automation Guide
Item
The values are mapped as per the definitions listed in Table 5-22.
Definition
Scale Factor
1
Unsigned High Order Word LSW
1
Unsigned Low Order Word MSW
1
Unsigned High Order Word LSW
1
Unsigned Low Order Word MSW
1
Unsigned High Order Word LSW
1
Unsigned Low Order Word MSW
1
Unsigned High Order Word LSW
1
Unsigned Low Order Word MSW
1
Unsigned High Order Word LSW
1
Unsigned Low Order Word MSW
1
Unsigned High Order Word LSW
1
Unsigned Low Order Word MSW
1
Unsigned High Order Word LSW
1
Unsigned Low Order Word MSW
1
Unsigned High Order Word LSW
1
Unsigned Low Order Word MSW
100
Unsigned Byte – 8 bits represented in a 16
bit format
N/A
INTERPRETED WORD
Bits 15 – 9 Not Used (mSW)
Bit 8 Quantity Sign: 1 = Pos. 0 = Neg.
Bit 7 Status: 0 = Leading 1 = Lagging
Bit 0 – 6
N/A
Bits 15 – 9 : Not Used (mSW)
Bit 8: Quantity Sign: 1 = Pos. 0 = Neg.
Bit 7: Status: 0 = Leading 1 = Lagging
Bit 0 – 6 : Power Factor * 100 (lSW)
100
Signed 16 Bits
1
0 = Leading 1 = Lagging
Description
Unsigned 32 Bit High Order Word MSW
Unsigned 32 Bit Low Order Word LSW
Unsigned 32 Bit High Order Word MSW
Unsigned 32 Bit Low Order Word LSW
Unsigned 32 Bit High Order Word MSW
Unsigned 32 Bit Low Order Word LSW
Unsigned 32 Bit High Order Word MSW
Unsigned 32 Bit Low Order Word LSW
Unsigned 32 Bit High Order Word MSW
Unsigned 32 Bit Low Order Word LSW
Unsigned 32 Bit High Order Word MSW
Unsigned 32 Bit Low Order Word LSW
Unsigned 32 Bit High Order Word MSW
Unsigned 32 Bit Low Order Word LSW
Unsigned 32 Bit High Order Word MSW
Description
Power Factor * 100 (lSW)
95

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tpu2000r

Table of Contents