P0112
Monitor:
• Continuous
Disable Criteria:
• None
Enable Criteria:
• Engine running
Malfunction Criteria:
• Inlet air temperature > 119°C (246°F) for time > 1.5 secs
Potential failure modes:
• Signal short circuit
• Sensor failure
Diagnostic Mask:
• The MIL will be illuminated if these faults are present for 2 consecutive trips.
P0113
Monitor:
• Continuous
Disable Criteria:
• None
Enable Criteria:
• Engine running
Malfunction Criteria:
• Inlet air temperature < –40°C (–104°F) for time > 1.5 secs
Potential failure modes:
• Signal open circuit
• Sensor failure
Diagnostic Mask:
• The MIL will be illuminated if these faults are present for 2 consecutive trips.